Literature DB >> 15373604

Comparison of tube and gel techniques for antibody identification.

M C Novaretti1, E J Silveira, E C Filho, P E Dorlhiac-Llacer, D A Chamone.   

Abstract

There are several methods for antibody detection and each technique has advantages and limitations. We compared the performance of the tube (polyethylene glycol-indirect antiglobulin test [PEG-IAT]) and gel test technique for antibody identification. From January to May 1999, we performed antibody screening tests by gel and tube techniques on 10,123 random blood samples submitted to our reference laboratory. Six hundred and twenty-eight (6.2%) reactive samples were tested for antibody specificity by both methods. One hundred and ninety-six were reactive only by gel: 25 anti-D, 33 anti-C, 76 anti-E, 13 anti-c, 5 anti-e, 18 anti-K, 7 anti-Jka, 2 anti-Dia, 3 anti-S, 8 combination Rh antibodies (1 with anti- K), and 6 other antibody specificities. Two samples were reactive only by PEG-IAT: 1 anti-K and 1 anti-Dia. Four hundred and thirty were positive by the two methods: 156 anti-D, 9 anti-C, 68 anti-E, 15 anti-c, 6 anti-e, 61 anti-K, 12 anti-Jka, 17 anti-Dia, 5 anti-S, 73 combination Rh antibodies (2 with anti-K), and 8 other antibody specificities. Based on this study, the gel test is more sensitive (p <.01) than the tube test for identifying potentially clinically significant antibodies.

Entities:  

Year:  2000        PMID: 15373604

Source DB:  PubMed          Journal:  Immunohematology        ISSN: 0894-203X


  5 in total

1.  Comparison of conventional tube test technique and gel microcolumn assay for direct antiglobulin test: a large study.

Authors:  M C Z Novaretti; E Jens; T Pagliarini; S L Bonifacio; P E Dorlhiac-Llacer; D A F Chamone
Journal:  J Clin Lab Anal       Date:  2004       Impact factor: 2.352

2.  Use of gel microcolumn assay for the detection of drug-induced positive direct antiglobulin tests.

Authors:  M C Z Novaretti; C R Sopeleti; P E Dorlhiac-Llacer; D A F Chamone
Journal:  J Clin Lab Anal       Date:  2005       Impact factor: 2.352

3.  Comparative Study of Blood Cross Matching Using Conventional Tube and Gel Method.

Authors:  D Swarup; P S Dhot; J Kotwal; A K Verma
Journal:  Med J Armed Forces India       Date:  2011-07-21

4.  Antibody elutions in Thai patients with a positive direct antiglobulin test.

Authors:  Oytip Nathalang; Pramote Sriwanitchrak; Jintana Tubrod; Pawinee Kupatawintu
Journal:  Blood Transfus       Date:  2010-09-13       Impact factor: 3.443

5.  Detection of naturally occurring alloantibody by an in-clinic antiglobulin-enhanced and standard crossmatch gel column test in non-transfused domestic shorthair cats.

Authors:  Isabelle Goy-Thollot; Alexandra Nectoux; Maryline Guidetti; Benjamin Chaprier; Sarah Bourgeois; Catherine Boisvineau; Anthony Barthélemy; Céline Pouzot-Nevoret; Urs Giger
Journal:  J Vet Intern Med       Date:  2018-12-17       Impact factor: 3.333

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.