Literature DB >> 15370497

Mechanically braked Wingate powers: agreement between SRM, corrected and conventional methods of measurement.

James Balmer1, Steve Bird, R C Richard Davison, Mike Doherty, Paul Smith.   

Abstract

In this study, we assessed the agreement between the powers recorded during a 30 s upper-body Wingate test using three different methods. Fifty-six men completed a single test on a Monark 814E mechanically braked ergometer fitted with a Schoberer Rad Messtechnik (SRM) powermeter. A commercial software package (Wingate test kit version 2.21, Cranlea, UK) was used to calculate conventional and corrected (with accelerative forces) values of power based on a resistive load (5% body mass) and flywheel velocity. The SRM calculated powers based on torque (measured at the crank arm) and crank rate. Values for peak 1 and 5 s power and mean 30 s power were measured. No significant differences (P >0.05) were found between the three methods for 30 s power values. However, the corrected values for peak 1 and 5 s power were 36 and 23% higher (P <0.05) respectively than those for the conventional method, and 27 and 16% higher (P <0.05) respectively than those for the SRM method. The conventional and SRM values for peak 1 and 5 s power were similar (P >0.05). Power values recorded using each method were influenced by sample time (P <0.05). Our results suggest that these three measures of power are similar when sampled over 30 s, but discrepancies occur when the sample time is reduced to either 1 or 5 s.

Entities:  

Mesh:

Year:  2004        PMID: 15370497     DOI: 10.1080/02640410310001655831

Source DB:  PubMed          Journal:  J Sports Sci        ISSN: 0264-0414            Impact factor:   3.337


  4 in total

1.  Cardiorespiratory fitness and aerobic performance adaptations to a 4-week sprint interval training in young healthy untrained females.

Authors:  Mykolas Kavaliauskas; Thomas P Steer; John A Babraj
Journal:  Sport Sci Health       Date:  2016-09-14

Review 2.  Caveats and Recommendations to Assess the Validity and Reliability of Cycling Power Meters: A Systematic Scoping Review.

Authors:  Anthony Bouillod; Georges Soto-Romero; Frederic Grappe; William Bertucci; Emmanuel Brunet; Johan Cassirame
Journal:  Sensors (Basel)       Date:  2022-01-05       Impact factor: 3.576

3.  Neuronal adenosine A2A receptors signal ergogenic effects of caffeine.

Authors:  Aderbal S Aguiar; Ana Elisa Speck; Paula M Canas; Rodrigo A Cunha
Journal:  Sci Rep       Date:  2020-08-07       Impact factor: 4.379

4.  Validity of the Favero Assioma Duo Power Pedal System for Measuring Power Output and Cadence.

Authors:  Almudena Montalvo-Pérez; Lidia B Alejo; Pedro L Valenzuela; Mario Castellanos; Jaime Gil-Cabrera; Eduardo Talavera; Alejandro Lucia; David Barranco-Gil
Journal:  Sensors (Basel)       Date:  2021-03-24       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.