Literature DB >> 15365718

Skill dependence of radiation exposure for the orthopaedic surgeon during interlocking nailing of long-bone shaft fractures: a clinical study.

Thomas R Blattert1, Ute A Fill, Elmar Kunz, Werner Panzer, Arnulf Weckbach, Dieter F Regulla.   

Abstract

INTRODUCTION: The objective of this clinical trial was to determine whether there is a skill dependence for the total amount of radiation exposure to orthopaedic surgeons caused by fluoroscopy during intramedullary fracture fixation.
MATERIALS AND METHODS: Surgical teams were assigned to either the 'Senior group' or the 'Junior group' according to their professional qualification and clinical appointment. Twenty-two long-bone shaft fractures were stabilized with intramedullary nails. The radiation exposure was measured at different body locations including fingers, trunk and head by means of thermoluminescent LiF:Mg,Cu,P detectors. The total time of fluoroscopy was registered for each operation.
RESULTS: Mean time of fluoroscopy per operation was 4.43 min for the 'Senior group' and 6.95 min for the 'Junior group'. The surgeons' hands were exposed to markedly higher doses (range 0-2.88 mSv 'Senior group'; 0-11.94 mSv 'Junior group') than their trunk and head (range 0-0.27 mSv 'Senior group'; 0-0.38 mSv 'Junior group'). After analysis of variance, differences between both groups proved to be statistically significant for all fingers measured (p</=0.02) and for the total time of fluoroscopy (p=0.019).
CONCLUSIONS: Generally, the hands are at higher risk than are the trunk and the head, and this finding is independent of surgical skills. However, an additional hazard is created for the less experienced surgeon by a highly varying and poorly predictable exposure of the hands and time needed for fluoroscopy. Thus, the use of radiation is more consistent and standardized with a skilled surgeon.

Entities:  

Mesh:

Year:  2004        PMID: 15365718     DOI: 10.1007/s00402-004-0743-9

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  23 in total

Review 1.  Occupational radiation doses to operators performing fluoroscopically-guided procedures.

Authors:  Kwang Pyo Kim; Donald L Miller; Amy Berrington de Gonzalez; Stephen Balter; Ruth A Kleinerman; Evgenia Ostroumova; Steven L Simon; Martha S Linet
Journal:  Health Phys       Date:  2012-07       Impact factor: 1.316

2.  Radiation exposure to the orthopaedic surgeon during periacetabular osteotomy.

Authors:  Inger Mechlenburg; Henrik Daugaard; Kjeld Søballe
Journal:  Int Orthop       Date:  2008-10-29       Impact factor: 3.075

3.  Olecranon anatomy: Use of a novel proximal interlocking screw for intramedullary nailing, a cadaver study.

Authors:  Fatih Küçükdurmaz; Necdet Saglam; Ismail Ağır; Cengiz Sen; Fuat Akpınar
Journal:  World J Orthop       Date:  2013-07-18

4.  [X-ray in trauma and orthopedic surgery. Physical and biological impact, reasonable use, and radiation protection in the operating room].

Authors:  K Dresing
Journal:  Oper Orthop Traumatol       Date:  2011-02       Impact factor: 1.154

5.  Measuring the radiation exposed with optically stimulated luminescent dosimeters and evaluation of the total time and dose of fluoroscopy.

Authors:  Sever Çaglar; Yaşar Mahsut Dinçel; Yavuz Arıkan; Osman Nuri Özyalvaç; Barış Özkul; Ali Öner
Journal:  J Clin Orthop Trauma       Date:  2018-07-21

6.  Is there a need for standardized postoperative radiographs after operative treatment of wrist or ankle fractures?

Authors:  Florian Oehme; Björn Christian Link; Herman Frima; Tim Schepers; Steven J Rhemrev; Reto Babst; Frank J P Beeres
Journal:  Eur J Trauma Emerg Surg       Date:  2018-07-07       Impact factor: 3.693

7.  Fluoroscopic freehand and electromagnetic-guided targeting system for distal locking screws of humeral intramedullary nail.

Authors:  P Persiani; M Gurzi; O Moreschini; G Di Giacomo; C Villani
Journal:  Musculoskelet Surg       Date:  2016-11-22

8.  Reducing intraoperative duration and ionising radiation exposure during the insertion of distal locking screws of intramedullary nails: a small-scale study comparing the current fluoroscopic method against radiation-free, electromagnetic navigation.

Authors:  Darren Grimwood; Jane Harvey-Lloyd
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-08-25

9.  Radiation Exposure of the Hand and Chest during C-arm Fluoroscopy-Guided Procedures.

Authors:  Cheol Hee Jung; Jae Sung Ryu; Seung Woo Baek; Ji Hye Oh; Nam Sik Woo; Hae Kyoung Kim; Jae Hun Kim
Journal:  Korean J Pain       Date:  2013-01-04

10.  Dosimetry during intramedullary nailing of the tibia.

Authors:  George Kirousis; Harry Delis; Panagiotis Megas; Elias Lambiris; George Panayiotakis
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.