Literature DB >> 15363496

A review of the development of Respimat Soft Mist Inhaler.

R Dalby1, M Spallek, T Voshaar.   

Abstract

Respimat Soft Mist Inhaler (SMI) is a new generation inhaler from Boehringer Ingelheim developed for use with respiratory drugs. The device functions by forcing a metered dose of drug solution through a unique and precisely engineered nozzle (the uniblock), producing two fine jets of liquid that converge at a pre-set angle. The collision of these two jets generates the soft mist. The soft mist contains a high fine particle fraction of approximately 65 to 80%. This is higher than aerosol clouds from conventional portable inhaler devices, such as pressurised metered dose inhalers (pMDIs) and dry powder inhalers (DPIs). In addition, the relatively long generation time of the aerosol cloud (approximately 1.5s) facilitates co-ordination of inhalation and actuation--a major problem with pMDIs. These features, together with the slow velocity of the soft mist, result in larger amounts of the drug reaching the lungs and less being deposited in the oropharynx compared with either pMDIs or DPIs. Generation of the soft mist from Respimat SMI is purely mechanical, so propellants are not necessary. The innovative design of Respimat SMI, using water-based drug formulations, ensures patients receive consistent and reliable doses of the drug with each actuation. The device was initially tested in scintigraphic lung deposition studies and produced encouraging results when compared with the chlorofluorocarbon-based pMDI (CFC-MDI). Subsequent clinical studies have confirmed that Respimat SMI is effective and safe in delivering bronchodilators to patients with asthma or chronic obstructive pulmonary disease.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15363496     DOI: 10.1016/j.ijpharm.2004.06.018

Source DB:  PubMed          Journal:  Int J Pharm        ISSN: 0378-5173            Impact factor:   5.875


  46 in total

1.  Condensational growth of combination drug-excipient submicrometer particles for targeted high efficiency pulmonary delivery: comparison of CFD predictions with experimental results.

Authors:  P Worth Longest; Michael Hindle
Journal:  Pharm Res       Date:  2011-09-27       Impact factor: 4.200

2.  Process Analytical Quality Control of Tailored Drug Release Formulation Prepared via Hot-Melt Extrusion Technology.

Authors:  Jun-Bom Park; Beom-Jin Lee; Chin-Yang Kang; Michael A Repka
Journal:  J Drug Deliv Sci Technol       Date:  2017-01-25       Impact factor: 3.981

Review 3.  A path to successful patient outcomes through aerosol drug delivery to children: a narrative review.

Authors:  Arzu Ari
Journal:  Ann Transl Med       Date:  2021-04

Review 4.  Devices for Improved Delivery of Nebulized Pharmaceutical Aerosols to the Lungs.

Authors:  Worth Longest; Benjamin Spence; Michael Hindle
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2019-07-09       Impact factor: 2.849

Review 5.  Aerosol delivery via invasive ventilation: a narrative review.

Authors:  Hui-Ling Lin; James B Fink; Huiqing Ge
Journal:  Ann Transl Med       Date:  2021-04

6.  Aerosol Delivery of siRNA to the Lungs. Part 1: Rationale for Gene Delivery Systems.

Authors:  Susanne R Youngren-Ortiz; Nishant S Gandhi; Laura España-Serrano; Mahavir B Chougule
Journal:  Kona       Date:  2015-09-30       Impact factor: 2.897

Review 7.  Tiotropium Respimat®: A Review of Its Use in Asthma Poorly Controlled with Inhaled Corticosteroids and Long-Acting β2-Adrenergic Agonists.

Authors:  Kate McKeage
Journal:  Drugs       Date:  2015-05       Impact factor: 9.546

8.  Validating CFD Predictions of Pharmaceutical Aerosol Deposition with In Vivo Data.

Authors:  Geng Tian; Michael Hindle; Sau Lee; P Worth Longest
Journal:  Pharm Res       Date:  2015-05-06       Impact factor: 4.200

9.  Condensational growth of combination drug-excipient submicrometer particles for targeted high-efficiency pulmonary delivery: evaluation of formulation and delivery device.

Authors:  Michael Hindle; P Worth Longest
Journal:  J Pharm Pharmacol       Date:  2012-02-21       Impact factor: 3.765

Review 10.  Use of Respimat Soft Mist inhaler in COPD patients.

Authors:  Paula Anderson
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2006
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.