Literature DB >> 1536108

Accuracy of ST/heart rate index in the diagnosis of coronary artery disease.

A P Morise1, R D Duval.   

Abstract

The accuracy of ST/heart rate (ST HR) index was evaluated in patients presenting for exercise electrocardiography with suspected coronary disease. In all, 420 patients (235 men and 185 women) with normal electrocardiograms at rest underwent exercise testing, followed within 3 months by coronary angiography. The sensitivity and specificity for standard ST criteria (greater than or equal to 1 mm horizontal or downsloping depression) were 48% (78 of 162) and 81% (208 of 258), respectively. An ST HR-index threshold of 1.86 microV/beta/min had the exact same specificity with a sensitivity of 44% (71 of 162; p = not significant). Consideration of greater than or equal to 1.5 mm upsloping depression had no significant impact on the aforementioned results. Using multivariate logistic regression analysis, age, sex, symptoms, cigarette smoking, diabetes mellitus, qualitative ST slope, rate-pressure product, METs achieved and exercise angina were evaluated with and without ST HR index and ST depression. According to this analysis, age, sex, symptoms and ST slope were good predictors of presence or absence of disease. Neither ST HR index nor ST depression had significance in the multivariate analysis. However, when a separate analysis was performed in men and women, the 2 quantitative ST variables showed significance in men, but not in women. Comparisons of discriminative accuracy using receiver-operating characteristic curves demonstrated differences between men and women, but no difference between ST HR index and ST depression. Therefore, concerning questions of coronary disease diagnosis, consideration of ST HR index was not better than standard ST criteria, and added nothing to multivariate analysis of other available variables.

Entities:  

Mesh:

Year:  1992        PMID: 1536108     DOI: 10.1016/0002-9149(92)90149-s

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  2 in total

Review 1.  Intraoperative automated ST segment analysis: a reliable 'black box'?

Authors:  H Yang
Journal:  Can J Anaesth       Date:  1996-10       Impact factor: 5.063

2.  Accuracy of exercise testing in the assessment of the severity of myocardial ischemia as determined by means of technetium-99m tetrofosmin SPECT scintigraphy.

Authors:  A R Galassi; S Azzarelli; L Lupo; C Mammana; R Foti; C Tamburino; S Musumeci; G Giuffrida
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.