Literature DB >> 15358496

Effect of source variability and transport processes on carbon isotope ratios of TCE and PCE in two sandy aquifers.

D Hunkeler1, N Chollet, X Pittet, R Aravena, J A Cherry, B L Parker.   

Abstract

Chlorinated ethenes often migrate over extended distances in aquifers and may originate from different sources. The aim of this study was to determine whether stable carbon isotope ratios remain constant during dissolution and transport of chlorinated ethenes and whether the ratios can be used to link plumes to their sources. Detailed depth-discrete delineation of the carbon isotope ratio in a tetrachloroethene (PCE) plume and in a trichloroethene (TCE) plume was done along cross-sections orthogonal to groundwater flow in two sandy aquifers in the Province of Ontario, Canada. At the TCE site, TCE concentrations up to solubility were measured in one high concentration zone close to the bottom of the aquifer from where dense non-aqueous phase liquid (DNAPL) was collected. A laboratory experiment using the DNAPL indicated that only very small carbon isotope fractionation occurs during dissolution of TCE (0.26 per thousand), which is consistent with field observations. At most sampling points, the delta(13)C of dissolved TCE was similar to that of the DNAPL except for a few sampling points at the bottom of the aquifer close to the underlying aquitard. At these points, a (13)C enrichment of up to 2.4 per thousand was observed, which was likely due to biodegradation and possibly preferential diffusion of TCE with (12)C into the aquitard. In contrast to the TCE site, several distinct zones of high concentration were observed at the PCE site and from zones to zone, the delta(13)C values varied substantially from -24.3 per thousand to -33.6 per thousand. Comparison of the delta(13)C values in the high concentration zones made it possible to divide the plume in the three different domains, each probably representing a different episode and location of DNAPL release. The three different zones could still be distinguished 220 m from the DNAPL sources. This demonstrates that carbon isotope ratios can be used to differentiate between different zones in chlorinated ethene plumes and to link plume zones to their sources. In addition, subtle variations in delta(13)C at plume fringes provided insight into mechanisms of plume spreading in transverse vertical direction. These variations were identified because of the high-resolution provided by the monitoring network.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15358496     DOI: 10.1016/j.jconhyd.2004.03.003

Source DB:  PubMed          Journal:  J Contam Hydrol        ISSN: 0169-7722            Impact factor:   3.188


  3 in total

1.  Performance of different assessment methods to evaluate contaminant sources and fate in a coastal aquifer.

Authors:  C Sbarbati; N Colombani; M Mastrocicco; R Aravena; M Petitta
Journal:  Environ Sci Pollut Res Int       Date:  2015-05-27       Impact factor: 4.223

2.  Stable carbon isotope fractionation in chlorinated ethene degradation by bacteria expressing three toluene oxygenases.

Authors:  Scott R Clingenpeel; Jaina L Moan; Danielle M McGrath; Bruce A Hungate; Mary E Watwood
Journal:  Front Microbiol       Date:  2012-02-20       Impact factor: 5.640

3.  Modelling of C/Cl isotopic behaviour during chloroethene biotic reductive dechlorination: Capabilities and limitations of simplified and comprehensive models.

Authors:  Alice Badin; Fabian Braun; Landon J S Halloran; Julien Maillard; Daniel Hunkeler
Journal:  PLoS One       Date:  2018-08-22       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.