Literature DB >> 15355499

External quality assessment for the detection of blood-borne viruses in plasma by nucleic acid amplification technology: the first human immunodeficiency virus and hepatitis B virus studies (HIV EQA/1 and HBV EQA/1) and the fifth hepatitis C virus study (HCV EQA/5).

G Pisani1, K Cristiano, J Saldanha, M Wirz, G M Bisso, C Mele, G Gentili.   

Abstract

BACKGROUND AND OBJECTIVES: This External Quality Assessment (EQA) study was aimed at assessing the proficiency of blood centres and blood product manufacturers in detecting, by nucleic acid amplification technology (NAT), the possible contamination of plasma with hepatitis C virus (HCV), human immunodeficiency virus (HIV) and hepatitis B virus (HBV).
MATERIALS AND METHODS: Three independent panels, one for each virus, were prepared at the Istituto Superiore di Sanità (ISS) by diluting the respective reference preparations. NAT methods used by the EQA participants included polymerase chain reaction (PCR) assays by Roche, transcription-mediated amplification (TMA) assays by Chiron and in-house PCR assays.
RESULTS: Forty-three of the 45 participants (95.6%) in the HCV EQA/5 who used a validated method were consistently able to detect a nominal concentration of 100 IU/ml for all six major genotypes. In the case of the HIV EQA/1, all 35 participants detected the samples containing 1000 IU/ml HIV, while five (14.3%) did not identify the samples containing 100 IU/ml HIV. With respect to the HBV EQA/1, all 16 participants correctly identified the positive samples containing either 1000 IU/ml or 100 IU/ml HBV. No false-positive results were observed with any of the three panels.
CONCLUSIONS: The HCV EQA/5 showed an improved proficiency of laboratories as compared with the HCV EQA/4. In fact, HCV genotypes 1, 2, 3 and 5 were correctly identified in 100% of the assays and genotypes 4 and 6 in 97.8% of the assays. While most of the participants in the HIV EQA/1 showed a good level of proficiency, an excellent performance was shown by all participants in the HBV EQA/1.

Entities:  

Mesh:

Year:  2004        PMID: 15355499     DOI: 10.1111/j.1423-0410.2004.00544.x

Source DB:  PubMed          Journal:  Vox Sang        ISSN: 0042-9007            Impact factor:   2.144


  1 in total

1.  Follow-up on diagnostic proficiency of laboratories equipped to perform orthopoxvirus detection and quantification by PCR: the second international external quality assurance study.

Authors:  Matthias Niedrig; Hermann Meyer; Marcus Panning; Christian Drosten
Journal:  J Clin Microbiol       Date:  2006-04       Impact factor: 5.948

  1 in total