| Literature DB >> 15353706 |
M Tomás1, F Fernández, M Bakali, H Muller.
Abstract
The MITOM code was developed at UAB (Universitat Autònoma de Barcelona) for unfolding neutron spectrometric measurements with a Bonner spheres system (BSS). One of the main characteristics of this code is that an initial parameterisation of the neutron energy components (thermal, intermediate and fast) is needed. This code uses the Monte Carlo method and the Bayesian theorem to obtain a set of solutions achieving different criteria and conditions between calculated and measured count rates. The final solution is an average of the acceptable solutions. The MITOM code was tested for ISO sources and a good agreement was observed between the reference values and the unfolded ones for global magnitudes. The code was applied recently to characterise both thermal SIGMA and CANEL/T400 sources of the IRSN facilities. The results of these applications were very satisfactory as well.Entities:
Mesh:
Year: 2004 PMID: 15353706 DOI: 10.1093/rpd/nch384
Source DB: PubMed Journal: Radiat Prot Dosimetry ISSN: 0144-8420 Impact factor: 0.972