Literature DB >> 15352360

Micromachined array tip for multifocus fiber-based optical coherence tomography.

Victor X D Yang1, Nigel Munce, Julius Pekar, Maggie L Gordon, Stewart Lo, Norman E Marcon, Brian C Wilson, I Alex Vitkin.   

Abstract

High-resolution optical coherence tomography demands a large detector bandwidth and a high numerical aperture for real-time imaging, which is difficult to achieve over a large imaging depth. To resolve these conflicting requirements we propose a novel multifocus fiber-based optical coherence tomography system with a micromachined array tip. We demonstrate the fabrication of a prototype four-channel tip that maintains a 9-14-microm spot diameter with more than 500 microm of imaging depth. Images of a resolution target and a human tooth were obtained with this tip by use of a four-channel cascaded Michelson fiber-optic interferometer, scanned simultaneously at 8 kHz with geometric power distribution across the four channels.

Entities:  

Mesh:

Year:  2004        PMID: 15352360     DOI: 10.1364/ol.29.001754

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  5 in total

1.  Scalable multiplexing for parallel imaging with interleaved optical coherence tomography.

Authors:  Hee Yoon Lee; Tahereh Marvdashti; Lian Duan; Saara A Khan; Audrey K Ellerbee
Journal:  Biomed Opt Express       Date:  2014-08-27       Impact factor: 3.732

2.  Multifocal interferometric synthetic aperture microscopy.

Authors:  Yang Xu; Xiong Kai Benjamin Chng; Steven G Adie; Stephen A Boppart; P Scott Carney
Journal:  Opt Express       Date:  2014-06-30       Impact factor: 3.894

3.  Intraoperative handheld optical coherence tomography forward-viewing probe: physical performance and preliminary animal imaging.

Authors:  Cuiru Sun; Kenneth K C Lee; Barry Vuong; Michael D Cusimano; Alexander Brukson; Antonio Mauro; Nigel Munce; Brian K Courtney; Beau A Standish; Victor X D Yang
Journal:  Biomed Opt Express       Date:  2012-05-16       Impact factor: 3.732

4.  Multi-directional optical coherence tomography for retinal imaging.

Authors:  Andreas Wartak; Marco Augustin; Richard Haindl; Florian Beer; Matthias Salas; Marie Laslandes; Bernhard Baumann; Michael Pircher; Christoph K Hitzenberger
Journal:  Biomed Opt Express       Date:  2017-11-13       Impact factor: 3.732

5.  Dual-Channel Spectral Domain Optical Coherence Tomography Based on a Single Spectrometer Using Compressive Sensing.

Authors:  Luying Yi; Liqun Sun; Mingli Zou; Bo Hou
Journal:  Sensors (Basel)       Date:  2019-09-16       Impact factor: 3.576

  5 in total