Literature DB >> 15352013

Enantioseparations by capillary electro-chromatography: differences exhibited by normal- and reversed-phase versions of polysaccharide stationary phases.

Debby Mangelings1, Mohamed Maftouh, D Luc Massart, Yvan Vander Heyden.   

Abstract

The influence of using normal-phase and reversed-phase versions of four commercial polysaccharide stationary phases on chiral separations was investigated with capillary electrochromatography (CEC). Both versions of the stationary phases, Chiralcel OD, OJ, and Chiralpak AD, AS were tested for the separation of two basic, two acidic, a bifunctional, and a neutral compound. Different background electrolytes were used, two at low pH for the acid, bifunctional and neutral substances, and three at high pH for the basic, bifunctional and neutral ones. This setup allowed evaluating differences between both stationary-phase versions and between mobile-phase compositions on a chiral separation. Duplicate CEC columns of each stationary phase were in-house prepared and tested, giving information about the intercolumn reproducibility. In general, reversed-phase versions of the current commercial polysaccharide stationary phases are found to be best for reversed-phase CEC, even though at high pH no significant differences were seen between both versions. Most differences were observed at low pH. For acidic compounds, it was seen that an ammonium formate electrolyte performed best, which is also an excellent electrolyte if coupling with mass spectrometry is desired. For basic, bifunctional and neutral compounds, no significant differences between the three tested electrolytes were observed at high pH. Here, a phosphate buffer is preferred as electrolyte because of its buffering capacities. However, if coupling to mass spectrometry is wanted, the more volatile ammonium bicarbonate electrolyte can be used as an alternative.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15352013     DOI: 10.1002/elps.200405927

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  2 in total

1.  High Throughput Analysis of Chiral Compounds Using Capillary Electrochromatography (CEC) and CEC-Mass Spectrometry with Cellulose Based Stationary Phases.

Authors:  William Bragg; Shahab A Shamsi
Journal:  Sep Sci Technol       Date:  2013       Impact factor: 2.475

2.  Sulfated and sulfonated polysaccharide as chiral stationary phases for capillary electrochromatography and capillary electrochromatography-mass spectrometry.

Authors:  Jie Zheng; William Bragg; Jingguo Hou; Na Lin; Sekar Chandrasekaran; Shahab A Shamsi
Journal:  J Chromatogr A       Date:  2008-12-06       Impact factor: 4.759

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.