Literature DB >> 15351050

Development and validation of a novel LC/ELSD method for the quantitation of gentamicin sulfate components in pharmaceuticals.

Nikolaos C Megoulas1, Michael A Koupparis.   

Abstract

The equivalent response of evaporative light scattering detector (ELSD) for compounds of similar structure is exploited to develop an LC/ELSD method for the simultaneous quantitation of the four main components of gentamicin sulfate, using as external standard the one main component kanamycin. A C18 column was used along with a mobile phase consisting of H2O (containing 35.4 microg/ml of trichloroacetic acid and 0.89 microl/ml of trifluoroacetic acid)-methanol-acetonitrile (990:5:5, v/v/v), in an isocratic mode at 1.1 ml/min. Parameters of ELSD were 50 degrees C for evaporation temperature and 3.0 bar for pressure of carrier gas (N2). A logarithmic calibration curve was obtained for sulfate (tR = 1.9 min) from 4.2 to 150 microg/ml (r > 0.994) with a precision of 0.18%R.S.D. Kanamycin and the four gentamicin components (C(1a), C2, C(2a) and C1) were eluted at 3.2, 4.6, 5.9, 7.1 and 8.7 min, respectively, with good resolution (Rs > 1.5). Logarithmic calibration curve was obtained for each component (r > 0.99) with statistically equal slopes varying from 2.457 to 2.558. The mass range of total gentamycin was 35-240 microg/ml. The proposed method was applied for the determination of gentamicin components and sulfate in raw materials and pharmaceutical formulations (injection, drops and cream) without any pretreatment except cream, for which liquid-liquid extraction was required. Recovery from standard addition experiments in commercial formulations was 99-100% regarding total gentamicin and 89-108% regarding individual components, with a precision (%RSD, n = 4) 0.7-5.8%.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15351050     DOI: 10.1016/j.jpba.2004.05.018

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  4 in total

1.  Niosome-encapsulated gentamicin for ophthalmic controlled delivery.

Authors:  Ghada Abdelbary; Nashwa El-Gendy
Journal:  AAPS PharmSciTech       Date:  2008-06-18       Impact factor: 3.246

2.  Determination of Gentamicin Sulphate Composition and Related Substances in Pharmaceutical Preparations by LC with Charged Aerosol Detection.

Authors:  Karolina Stypulkowska; Agata Blazewicz; Zbigniew Fijalek; Katarzyna Sarna
Journal:  Chromatographia       Date:  2010-10-01       Impact factor: 2.044

3.  Development of a multicommutated flow system with chemiluminometric detection for quantification of gentamicin in pharmaceuticals.

Authors:  Lúcia H M L M Santos; A N Araújo; Boaventura Reis; M C B S M Montenegro
Journal:  J Autom Methods Manag Chem       Date:  2010-10-13

4.  The impact of storage conditions upon gentamicin coated antimicrobial implants.

Authors:  Nicholas D Mullins; Benjamin J Deadman; Humphrey A Moynihan; Florence O McCarthy; Simon E Lawrence; Jonathan Thompson; Anita R Maguire
Journal:  J Pharm Anal       Date:  2016-05-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.