Quantification of the bone-related mRNAs at the bone/prosthetic interface.

J A Hunt1, D F Williams, C R Howlett, H Zreiqat, B Zicat.   

Abstract

Aseptic loosening is one of the major reasons for failure of joint prostheses. The periprosthetic tissue has previously been described microscopically; however, little work has been devoted towards quantitating genes expressed by cells at the materials/tissue interface. This study aims to characterize the phenotypic expression of osteoblasts and test the feasibility of quantifying the level of gene expression in periprosthetic tissue sections by combining in situ hybridization and image analysis techniques. There are many factors to consider when quantifying mRNA, in that comparing labeling between different cDNA probes, these should have comparable length and base comparison. The probes should be labeled with the same specific activity, that is the amount of probe to label added is the same, both between different probes and between batches of the same probe. Chromagen color reactions are variable in that the color development is not always linear and more likely follows a sigmoidal curve. Samples should only be compared when it is known that the reaction has been in the linear range. The image analysis of such staining introduces further factors which should be considered and controlled. Color analysis is a very complex problem with respect to reproducibly analyzing histological sections. The brightness component of the image should be independent of the colors within the image, in conventional RGB (red, green and blue) signalling mode this is not possible, while when using HSI (hue saturation and intensity) mode this becomes possible, and factors like staining intensity and brightness of the image become much more accountable and controllable. With these factors identified, we consider that the quantitative image analysis approach does allow comparison of patterns of bone-related mRNAs and demonstrates differences in expression in these osteogenic factors depending on distance from the prosthesis, tissue type, patient and device. Copyright 1998 Kluwer Academic Publishers

Entities:  

Year:  1998        PMID: 15348923     DOI: 10.1023/a:1008930331180

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  4 in total

1.  Modulation of the phenotypic and functional properties of phagocytic macrophages by wear particles from orthopaedic implants.

Authors:  N Al-Saffar; P A Revell; A Kobayashi
Journal:  J Mater Sci Mater Med       Date:  1997-11       Impact factor: 3.896

2.  Bone formation and bone resorption in failed total joint arthroplasties: histomorphometric analysis with histochemical and immunohistochemical technique.

Authors:  Y Kadoya; P A Revell; N al-Saffar; A Kobayashi; G Scott; M A Freeman
Journal:  J Orthop Res       Date:  1996-05       Impact factor: 3.494

3.  A novel technique for quantitative detection of mRNA expression in human bone derived cells cultured on biomaterials.

Authors:  H Zreiqat; B Markovic; W R Walsh; C R Howlett
Journal:  J Biomed Mater Res       Date:  1996

4.  Production of cytokines around loosened cemented acetabular components. Analysis with immunohistochemical techniques and in situ hybridization.

Authors:  W A Jiranek; M Machado; M Jasty; D Jevsevar; H J Wolfe; S R Goldring; M J Goldberg; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1993-06       Impact factor: 5.284

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.