Reliability of PMMA bone cement fixation: fracture and fatigue crack-growth behaviour.

N C Nguyen1, W J Maloney, R H Dauskardt.   

Abstract

Fracture mechanics tests were performed to characterize the fracture toughness and fatigue crack-growth behaviour of polymethylmethacrylate (PMMA) bone cement, commonly used in joint replacement surgery. Compact tension specimens of various thicknesses were prepared and tested in both air and Ringer's solution. Contrary to previous reports citing toughness as a single valued parameter, the PMMA was found to exhibit resistance-curve behaviour with a plateau toughness of approximately 0.6 MPa m1/2 in air, and approximately 2.0 MPa m1/2 in Ringer's solution. The increased toughness in Ringer's solution is thought to arise from the plasticizing effect of the environment. Under cyclic loads, the material displayed true mechanical fatigue failure in both environments; fatigue crack-growth rates, da/dN, were measured over the range approximately 10(-10) to 10(-6) m/cycle and found to display a power-law dependence on the stress intensity range, DeltaK. The cement was found to be more resistant to fatigue-crack propagation in Ringer's solution than in air. Wear debris was observed on the fatigue fracture surfaces, particularly those produced in air. These findings and the validity of using a linear-elastic fracture mechanics approach for viscoelastic materials are discussed in the context of providing more reliable and fracture-resistant cemented joints.

Entities:  

Year:  1997        PMID: 15348713     DOI: 10.1023/a:1018574109544

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  14 in total

1.  Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty.

Authors:  E J Cheal; M Spector; W C Hayes
Journal:  J Orthop Res       Date:  1992-05       Impact factor: 3.494

2.  Cracks emanating from circular voids or elastic inclusions in PMMA near a bone-implant interface.

Authors:  V M Gharpuray; L M Keer; J L Lewis
Journal:  J Biomech Eng       Date:  1990-02       Impact factor: 2.097

3.  Pathology of the bone-cement interface in loosening of total hip replacement.

Authors:  U E Pazzaglia
Journal:  Arch Orthop Trauma Surg       Date:  1990       Impact factor: 3.067

4.  Metal sensitivity as a cause of bone necrosis and loosening of the prosthesis in total joint replacement.

Authors:  E M Evans; M A Freeman; A J Miller; B Vernon-Roberts
Journal:  J Bone Joint Surg Br       Date:  1974-11

5.  The effect of centrifugation on the fracture properties of acrylic bone cements.

Authors:  C M Rimnac; T M Wright; D L McGill
Journal:  J Bone Joint Surg Am       Date:  1986-02       Impact factor: 5.284

6.  Extensive porosity at the cement-femoral prosthesis interface: a preliminary study.

Authors:  S P James; T P Schmalzried; F J McGarry; W H Harris
Journal:  J Biomed Mater Res       Date:  1993-01

7.  The effects of micromotion and particulate materials on tissue differentiation. Bone chamber studies in rabbits.

Authors:  S B Goodman
Journal:  Acta Orthop Scand Suppl       Date:  1994-06

8.  Long-term compressive creep deformation and damage in acrylic bone cements.

Authors:  D J Chwirut
Journal:  J Biomed Mater Res       Date:  1984-01

9.  A characterization of polymethylmethacrylate bone cement.

Authors:  S S Haas; G M Brauer; G Dickson
Journal:  J Bone Joint Surg Am       Date:  1975-04       Impact factor: 5.284

10.  The fracture toughness of titanium-fiber-reinforced bone cement.

Authors:  L D Topoleski; P Ducheyne; J M Cuckler
Journal:  J Biomed Mater Res       Date:  1992-12
View more
  5 in total

1.  Mechanical properties of hydroxyapatite reinforced poly(ethylmethacrylate) bone cement after immersion in a physiological solution: influence of a silane coupling agent.

Authors:  E J Harper; M Braden; W Bonfield
Journal:  J Mater Sci Mater Med       Date:  2000-08       Impact factor: 3.896

Review 2.  Fracture Toughness of Acrylic PMMA Bone Cement: A Mini-Review.

Authors:  Ajay Kumar; Rajesh Ghosh
Journal:  Indian J Orthop       Date:  2021-08-21       Impact factor: 1.033

3.  Fatigue crack propagation under variable amplitude loading in PMMA and bone cement.

Authors:  S L Evans
Journal:  J Mater Sci Mater Med       Date:  2007-05-05       Impact factor: 3.896

4.  Ultrastructural evaluation of in vitro mineralized calcium phosphate phase on surface phosphorylated poly(hydroxy ethyl methacrylate-co-methyl methacrylate).

Authors:  G S Sailaja; P Ramesh; H K Varma
Journal:  J Mater Sci Mater Med       Date:  2010-01-23       Impact factor: 3.896

5.  Early fixation of cobalt-chromium based alloy surgical implants to bone using a tissue-engineering approach.

Authors:  Munehiro Ogawa; Yasuaki Tohma; Hajime Ohgushi; Yoshinori Takakura; Yasuhito Tanaka
Journal:  Int J Mol Sci       Date:  2012-05-09       Impact factor: 6.208

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.