Literature DB >> 15348635

Corrosion and permanent fracture resistance of coated and conventional orthodontic wires.

P Neumann1, C Bourauel, A Jäger.   

Abstract

The corrosion processes are presumed to have negative consequences on biocompatibility, aesthetic appearance and the frictional behavior between the bracket and the guiding arch during orthodontic treatment. A group of new guiding arches are the coated orthodontic wires. The present in-vitro study investigated the corrosion behavior and permanent fracture resistance of eight coated wires of different dimensions. Five superelastic nickel titanium (NiTi) wires (Titanol Low Force River Finish Gold and Gold 2: Forestadent Corp.; Titanol Superelastic tooth colored: Forestadent Corp.; Bioforce Sentalloy longuard: GAC Corp.; NiTi Imagination: GAC Corp.), two beta-titanium-wires (TMA Low Friction longuard: Ormco Corp.; TMA Low Friction longuard Purple: Ormco Corp.) and one steel wire (Stainless Steel Imagination: GAC Corp.) were selected. For comparison reasons three uncoated arch wires (Rematitan Lite Dimple: Dentaurum Corp.; Titanol Low Force River Finish: Forestadent Corp.; Bioforce Sentalloy: GAC Corp.) were included in the investigation. Surface modifications were made of teflon, polyethylene and by ion implantation. The corrosion processes have been carried out by the use of a specialized electrochemical cell. In a second experimental series the wires were exposed to mechanical stresses. Finally, all wires were examined in a scanning electron microscope. The results indicated that teflon coating prevented the corrosion of the wires. As expected, the beta-titanium wires did not corrode either. The other wires showed rupture potentials between 187 mV and 602 mV (NHE). After mechanical stress testing the wires could be subdivided into three groups. In the first group no differences could be recognized, the second group showed changes in their crystallographic structure and in the last group the teflon coating was peeled off from the surface of the wires.

Entities:  

Year:  2002        PMID: 15348635     DOI: 10.1023/a:1013831011241

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  12 in total

1.  CORROSION OF GOLD AND AMALGAM PLACED IN CONTACT WITH EACH OTHER.

Authors:  T FUSAYAMA; T KATAYORI; S NOMOTO
Journal:  J Dent Res       Date:  1963 Sep-Oct       Impact factor: 6.116

2.  Corrosion testing by potentiodynamic polarization in various electrolytes.

Authors:  R I Holland
Journal:  Dent Mater       Date:  1992-07       Impact factor: 5.304

3.  Surface roughness of orthodontic wires via atomic force microscopy, laser specular reflectance, and profilometry.

Authors:  C Bourauel; T Fries; D Drescher; R Plietsch
Journal:  Eur J Orthod       Date:  1998-02       Impact factor: 3.075

4.  [Corrosion behavior of different orthodontic wires].

Authors:  H F Kappert; I Jonas; M Liebermann; T Rakosi
Journal:  Fortschr Kieferorthop       Date:  1988-08

5.  Surface roughness of orthodontic archwires via laser spectroscopy.

Authors:  R P Kusy; J Q Whitley; M J Mayhew; J E Buckthal
Journal:  Angle Orthod       Date:  1988-01       Impact factor: 2.079

6.  [In-vivo corrosion studies of orthodontic appliances].

Authors:  B Kratzenstein; H Weber; J Geis-Gerstorfer; P Koppenburg
Journal:  Dtsch Zahnarztl Z       Date:  1985-11

7.  Proliferation of nickel-sensitive human lymphocytes by corrosion products of orthodontic appliances.

Authors:  M R Grímsdóttir; A Hensten-Pettersen; A Kullmann
Journal:  Biomaterials       Date:  1994-11       Impact factor: 12.479

8.  [The long-term fracture resistance of orthodontic nickel-titanium wires].

Authors:  D Drescher; C Bourauel; W Sonneborn; G P Schmuth
Journal:  Schweiz Monatsschr Zahnmed       Date:  1994

9.  Cytotoxic effect of orthodontic appliances.

Authors:  M R Grimsdottir; A Hensten-Pettersen; A Kullmann
Journal:  Eur J Orthod       Date:  1992-02       Impact factor: 3.075

10.  Induction of immunological tolerance by oral administration of nickel and chromium.

Authors:  K J Vreeburg; K de Groot; M von Blomberg; R J Scheper
Journal:  J Dent Res       Date:  1984-02       Impact factor: 6.116

View more
  13 in total

1.  Friction behavior of self-ligating and conventional brackets with different ligature systems.

Authors:  Alexandra Szczupakowski; Susanne Reimann; Cornelius Dirk; Ludger Keilig; Anna Weber; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2016-05-24       Impact factor: 1.938

2.  Comparison of frictional forces between aesthetic orthodontic coated wires and self-ligation brackets.

Authors:  Yunmi Kim; Jung-Yul Cha; Chung-Ju Hwang; Hyung Seog Yu; Seon Gun Tahk
Journal:  Korean J Orthod       Date:  2014-07-24       Impact factor: 1.372

3.  Evaluation of surface roughness of orthodontic wires by means of atomic force microscopy.

Authors:  Vincenzo D'Antò; Roberto Rongo; Gianluca Ametrano; Gianrico Spagnuolo; Paolo Manzo; Roberto Martina; Sergio Paduano; Rosa Valletta
Journal:  Angle Orthod       Date:  2012-02-15       Impact factor: 2.079

4.  Effects of intraoral aging on surface properties of coated nickel-titanium archwires.

Authors:  Roberto Rongo; Gianluca Ametrano; Antonio Gloria; Gianrico Spagnuolo; Angela Galeotti; Sergio Paduano; Rosa Valletta; Vincenzo D'Antò
Journal:  Angle Orthod       Date:  2013-12-05       Impact factor: 2.079

5.  Comparison of surface topography of low-friction and conventional TMA orthodontic arch wires using atomic force microscopy.

Authors:  Nouf I Alsabti; Christoph P Bourauel; Nabeel F Talic
Journal:  J Orthod Sci       Date:  2021-02-19

6.  Load-deflection and surface properties of coated and conventional superelastic orthodontic archwires in conventional and metal-insert ceramic brackets.

Authors:  Shiva Alavi; Navid Hosseini
Journal:  Dent Res J (Isfahan)       Date:  2012-03

7.  Static and kinetic frictional forces of silica-insert ceramic brackets with coated archwires in artificial saliva.

Authors:  Mostafa Shahabi; Soheil Salari; Maryam Poosti; Mostafa Abtahi
Journal:  Dent Res J (Isfahan)       Date:  2017 Nov-Dec

8.  Variations in surface roughness of seven orthodontic archwires: an SEM-profilometry study.

Authors:  Fariborz Amini; Vahid Rakhshan; Maryam Pousti; Hajir Rahimi; Mahsa Shariati; Bahareh Aghamohamadi
Journal:  Korean J Orthod       Date:  2012-06-28       Impact factor: 1.372

9.  Comparison of deflection forces of esthetic archwires combined with ceramic brackets.

Authors:  Murilo Matias; Marcos Roberto de Freitas; Karina Maria Salvatore de Freitas; Guilherme Janson; Rodrigo Hitoshi Higa; Manoela Fávaro Francisconi
Journal:  J Appl Oral Sci       Date:  2018-02-08       Impact factor: 2.698

10.  Effectiveness of medical coating materials in decreasing friction between orthodontic brackets and archwires.

Authors:  Nursel Arici; Berat S Akdeniz; Abdullah A Oz; Yucel Gencer; Mehmet Tarakci; Selim Arici
Journal:  Korean J Orthod       Date:  2021-07-25       Impact factor: 1.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.