Literature DB >> 15348562

Influence of test protocol in determining the blood response to model polymers.

G P A Michanetzis1, Y F Missirlis, N P Rhodes, D F Williams, R Eloy, W Lemm.   

Abstract

A multi-parametric, multi-center evaluation of three polymers was performed measuring their response to blood contact. The purpose of this study was to pinpoint differences in tests performed for assessing "basic" hemocompatibility on identical materials at different centers and attempt to rationalize. Assays for platelet adhesion, activation, aggregability and activation of the coagulation system in addition to an ex vivo patency assay were performed at four centers across Europe, using protocols favored by each center for determining the blood-contacting performance of a biomaterial. Three polymers were chosen for their expected blood response spanning the range of undesirable to desirable: ethylenevinylacetate (EVA), polyvinylchloride (PVC) and PVC modified with polyethylene oxide (PEO). The assays were ranked in terms of their efficacy compared to cost and simplicity. A correlation between assays was calculated, indicating the ability of one test to correctly determine the blood response compared to another. Some assays were unable to distinguish between materials, but of the assays which could, the materials were ranked in the following order: EVA; PVC; PVC-PEO, EVA producing the most undesirable response. It is concluded that many commonly used assays for determining hemocompatibility are inappropriate, but there are simple and reliable test methods available which correlate well with the more sophisticated protocols.

Entities:  

Year:  2002        PMID: 15348562     DOI: 10.1023/a:1016166807299

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  18 in total

1.  Platelet deposition on subendothelium exposed to flowing blood: mathematical analysis of physical parameters.

Authors:  V T Turitto; H R Baumgartner
Journal:  Trans Am Soc Artif Intern Organs       Date:  1975

2.  Rationale for the design of biomaterials and the evaluation of their biocompatibility.

Authors:  C Baquey; B Dupuy; G Janvier; L Bordenave; J Caix; B Basse-Cathalinat
Journal:  Biorheology       Date:  1991       Impact factor: 1.875

Review 3.  Nonthrombogenic surfaces: critical review.

Authors:  E W Salzman
Journal:  Blood       Date:  1971-10       Impact factor: 22.113

4.  Comparative in vivo and in vitro studies of fibrinopeptide A and factor XIII subunit A levels as indicators of thrombin generation.

Authors:  M J Galloway; B A McVerry; M J Mackie
Journal:  Thromb Res       Date:  1984-01-15       Impact factor: 3.944

5.  Influence of wall shear rate on parameters of blood compatibility of intravascular catheters.

Authors:  N P Rhodes; T V Kumary; D F Williams
Journal:  Biomaterials       Date:  1996-10       Impact factor: 12.479

Review 6.  Flow chambers and their standardization for use in studies of thrombosis. On behalf of the Subcommittee on Rheology of the Scientific and Standardization Committee of the ISTH.

Authors:  S M Slack; V T Turitto
Journal:  Thromb Haemost       Date:  1994-11       Impact factor: 5.249

7.  Importance of adsorption-desorption processes of plasma proteins in biomaterials hemocompatibility.

Authors:  V I Sevastianov; E A Tseytlina; A V Volkov; V I Shumakov
Journal:  Trans Am Soc Artif Intern Organs       Date:  1984

8.  A monoclonal antibody to a membrane glycoprotein binds only to activated platelets.

Authors:  R P McEver; M N Martin
Journal:  J Biol Chem       Date:  1984-08-10       Impact factor: 5.157

9.  Plasma protein adsorption to sulfonated poly(ethylene oxide)-grafted polyurethane surface.

Authors:  D K Han; K D Park; G H Ryu; U Y Kim; B G Min; Y H Kim
Journal:  J Biomed Mater Res       Date:  1996-01

10.  Rheological aspects of thrombosis and haemostasis: basic principles and applications. ICTH-Report--Subcommittee on Rheology of the International Committee on Thrombosis and Haemostasis.

Authors:  H L Goldsmith; V T Turitto
Journal:  Thromb Haemost       Date:  1986-06-30       Impact factor: 5.249