Three dimensional measurement of the surface topography of ceramic and metallic orthopaedic joint prostheses.

L Blunt1, X Q Jiang.   

Abstract

The comprehensive study of surface topography of the orthopaedic joint prostheses has become very important for analysis of the wear mechanism and the performance life of the joint replacement systems. The aim of the study to investigate "best" methods for the three-dimensional (3D) surface metrology of orthopaedic joint prostheses. Characterization techniques for the identification and evaluation of the functional features of the bearing surface topographies has been provided in previous work. This paper concentrates on addressing issues of measurement and application techniques for assessment of the 3D surface topography of the joint replacement systems by using contacting stylus instruments, atomic force microscopes (AFM), and non-contacting measurement supported by focus detection instruments and phase-shifting interferometers. The techniques are discussed according to different analysis requirements of the orthopaedic joint prostheses. This work also discusses the performances of the instruments in terms of the measurement of femoral heads. Finally, recommendations for acceptable measurement techniques and application for analyzing surface topography of orthopaedic joint prostheses are summarized. Copyright 2000 Kluwer Academic Publishers

Year:  2000        PMID: 15348038     DOI: 10.1023/a:1008924511967

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  6 in total

1.  The linear penetration rate is not relevant for evaluating wear of dual mobility cups: an explant study.

Authors:  Bertrand Boyer; Thomas Neri; Alexandre Di Iorio; Jean Geringer; Remi Philippot; Frederic Farizon
Journal:  Int Orthop       Date:  2017-01-26       Impact factor: 3.075

2.  Topographical analysis of the femoral components of ex vivo total knee replacements.

Authors:  Susan C Scholes; Emma Kennard; Rajkumar Gangadharan; David Weir; Jim Holland; David Deehan; Thomas J Joyce
Journal:  J Mater Sci Mater Med       Date:  2012-11-17       Impact factor: 3.896

3.  Long-term wear of dual mobility total hip replacement cups: explant study.

Authors:  Bertrand Boyer; Thomas Neri; Jean Geringer; Alexandre Di Iorio; Remi Philippot; Frederic Farizon
Journal:  Int Orthop       Date:  2017-06-03       Impact factor: 3.075

4.  Intraprosthetic dislocation of dual mobility total hip arthroplasty: still occurring?

Authors:  Thomas Neri; Bertrand Boyer; Jean Geringer; Alexandre Di Iorio; Jacques H Caton; Remi PhiIippot; Frederic Farizon
Journal:  Int Orthop       Date:  2018-07-19       Impact factor: 3.075

5.  Stereometric and Tribometric Studies of Polymeric Pin and Ceramic Plate Friction Pair Components.

Authors:  Magdalena Niemczewska-Wójcik; Artur Wójcik
Journal:  Materials (Basel)       Date:  2021-02-09       Impact factor: 3.623

6.  TiO2 Nanocoatings with Controllable Crystal Type and Nanoscale Topography on Zirconia Implants to Accelerate Bone Formation.

Authors:  Nan Li; Zhichao Liu; Guanqi Liu; Zhi Wang; Xianwei Guo; Chuanbin Guo; Jianmin Han
Journal:  Bioinorg Chem Appl       Date:  2022-04-12       Impact factor: 4.724

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.