Literature DB >> 15346703

Predicting blood pressure change caused by rapid injection of propofol during anesthesia induction with a logistic regression model.

Ruey-Horng Rau1, Yu-Chuan Li, Jen-Kun Cheng, Chien-Chuan Chen, Yuan-Pi Ko, Chun-Jen Huang.   

Abstract

BACKGROUND: Propofol is a common intravenous agent for induction and maintenance of anesthesia. The advantage of propofol is rapid recovery of consciousness when the continuous infusion is stopped. Additionally, it has antiemetic effect of reducing postoperative nausea and vomiting. On the other hand, rapid infusion of propofol is painful and may cause hypotension. In this study, we aimed to develop a logistic regression model to accurately predict blood pressure change caused by rapid infusion of propofol.
METHODS: Seventeen variables (including demographic data, past medical history, laboratory data, and blood pressure before induction) were assessed in 200 patients who received propofol for induction of anesthesia for routine surgery. A logistic regression model was derived using these values as independent variables to predict whether a patient would suffer a significant blood pressure change (> 30% decrease from baseline). Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were calculated to evaluate the performance of our prediction model.
RESULTS: A cut-off value of 0.17 in the logistic regression model predicted decreased blood pressure with 90.0% sensitivity and, 67.3% specificity. The area under the receiver operating characteristic curve was 0.855.
CONCLUSIONS: Our prediction model predicts propofol-induced hypotension with acceptable accuracy. Because of the straightforward mathematic formula used, our model can be integrated effortlessly into a hospital information system, providing a reliable and useful decision support for clinical anesthesia staff.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15346703

Source DB:  PubMed          Journal:  Acta Anaesthesiol Taiwan


  2 in total

1.  Predictors of hemodynamic compromise with propofol during defibrillator implantation: a single center experience.

Authors:  Khyati Pandya; Mehul B Patel; Jaya Natla; Abhijeet Dhoble; Terry Habetler; Jeffrey Holliday; Renee Janes; Sujeeth R Punnam; Joseph C Gardiner; Ranjan K Thakur
Journal:  J Interv Card Electrophysiol       Date:  2009-03-05       Impact factor: 1.900

2.  Prediction of hemodynamic fluctuations after induction of general anesthesia using propofol in non-cardiac surgery: a retrospective cohort study.

Authors:  Sho Kawasaki; Chikako Kiyohara; Shoji Tokunaga; Sumio Hoka
Journal:  BMC Anesthesiol       Date:  2018-11-10       Impact factor: 2.217

  2 in total