OBJECTIVES: We sought to determine if intravenously injected microbubbles would be retained by the carotid arteries (CAs) in the setting of endothelial dysfunction (ED) using a linear transducer equipped with a low mechanical index pulse sequence scheme (PSS). BACKGROUND: Microbubbles normally pass freely through large and small vessels but are retained in regions with ED. New high-frequency low mechanical index PSS can potentially be utilized to image these retained microbubbles. METHODS: Intravenous albumin- and lipid-encapsulated microbubbles were administered in seven pigs while imaging the CAs before and after a 20% intralipid infusion to induce hypertriglyceridemia. The degree of microbubble retention was quantified by measuring endothelial acoustic intensity (AI) after clearance of free-flowing microbubbles. Microbubble adherence was also evaluated after selective balloon injury of the CAs. The CA diameter responses to acetylcholine were quantified. RESULTS: After induction of hypertriglyceridemia, adherence of albumin-encapsulated microbubbles was visually evident in all CAs, and endothelial AI increased significantly (p < 0.001 compared with baseline). The CA responses to acetylcholine went from vasodilation at baseline to vasoconstriction during hypertriglyceridemia. Endothelial AI also increased in the balloon-stretched vessels (p < 0.01 compared with uninjured vessels) after albumin-encapsulated microbubble injection, with a ring of microbubbles selectively adhering to the injured segment. This retention was not observed with lipid-encapsulated microbubbles. Scanning electron microscopy confirmed that albumin-coated microbubbles adhered to endothelial cells. CONCLUSIONS: Retention of intravenously injected albumin microbubbles occurs in the setting of both global and regional ED in large vessels and can be noninvasively imaged with high-frequency low mechanical index PSS.
OBJECTIVES: We sought to determine if intravenously injected microbubbles would be retained by the carotid arteries (CAs) in the setting of endothelial dysfunction (ED) using a linear transducer equipped with a low mechanical index pulse sequence scheme (PSS). BACKGROUND: Microbubbles normally pass freely through large and small vessels but are retained in regions with ED. New high-frequency low mechanical index PSS can potentially be utilized to image these retained microbubbles. METHODS: Intravenous albumin- and lipid-encapsulated microbubbles were administered in seven pigs while imaging the CAs before and after a 20% intralipid infusion to induce hypertriglyceridemia. The degree of microbubble retention was quantified by measuring endothelial acoustic intensity (AI) after clearance of free-flowing microbubbles. Microbubble adherence was also evaluated after selective balloon injury of the CAs. The CA diameter responses to acetylcholine were quantified. RESULTS: After induction of hypertriglyceridemia, adherence of albumin-encapsulated microbubbles was visually evident in all CAs, and endothelial AI increased significantly (p < 0.001 compared with baseline). The CA responses to acetylcholine went from vasodilation at baseline to vasoconstriction during hypertriglyceridemia. Endothelial AI also increased in the balloon-stretched vessels (p < 0.01 compared with uninjured vessels) after albumin-encapsulated microbubble injection, with a ring of microbubbles selectively adhering to the injured segment. This retention was not observed with lipid-encapsulated microbubbles. Scanning electron microscopy confirmed that albumin-coated microbubbles adhered to endothelial cells. CONCLUSIONS: Retention of intravenously injected albumin microbubbles occurs in the setting of both global and regional ED in large vessels and can be noninvasively imaged with high-frequency low mechanical index PSS.
Authors: Daniel R Anderson; Michael J Duryee; Rajeev K Anchan; Robert P Garvin; Michael D Johnston; Thomas R Porter; Geoffrey M Thiele; Lynell W Klassen Journal: J Biol Chem Date: 2010-10-21 Impact factor: 5.157
Authors: Jonathan T Sutton; Kevin J Haworth; Gail Pyne-Geithman; Christy K Holland Journal: Expert Opin Drug Deliv Date: 2013-03-01 Impact factor: 6.648
Authors: Jonathan A Kopechek; Todd M Abruzzo; Boyu Wang; Stephen M Chrzanowski; Denise A B Smith; Patrick H Kee; Shaoling Huang; Joel H Collier; David D McPherson; Christy K Holland Journal: J Ultrasound Med Date: 2008-11 Impact factor: 2.153