Literature DB >> 15337205

Clinical and angiographic outcome after sirolimus-eluting stent implantation in aorto-ostial lesions.

Ioannis Iakovou1, Lei Ge, Iassen Michev, Giuseppe M Sangiorgi, Matteo Montorfano, Flavio Airoldi, Alaide Chieffo, Goran Stankovic, Giancarlo Vitrella, Mauro Carlino, Nicola Corvaja, Carlo Briguori, Antonio Colombo.   

Abstract

OBJECTIVES: This observational study evaluated the clinical and angiographic outcomes of patients with aorto-ostial coronary artery disease treated with sirolimus-eluting stents (SESs) or with bare metal stents (BMSs).
BACKGROUND: The safety and effectiveness of SESs for the treatment of aorto-ostial lesions have not been demonstrated.
METHODS: We identified 82 consecutive patients who underwent percutaneous coronary interventions in 82 aorto-ostial lesions using the SES (32 patients) or BMS (50 patients) and compared the two groups of patients. The incidence of major adverse cardiac events (MACE), including death or Q-wave myocardial infarction (MI), target lesion revascularization (TLR), and target vessel revascularization (TVR), were recorded in-hospital and at a 10-month follow-up.
RESULTS: All stents were implanted successfully. There were no statistically significant differences regarding major in-hospital complications between the two groups. At 10-month follow-up, two (6.3%) patients in the SES group and 14 (28%) patients in the BMS group underwent TLR (p = 0.01); MACE were less frequent in the SES group compared to the BMS group (19% vs. 44%, p = 0.02). Angiographic follow-up showed lower binary restenosis rates (11% vs. 51%, p = 0.001) and smaller late loss (0.21 +/- 0.31 mm vs. 2.06 +/- 1.37 mm, p < 0.0001) in the SES group.
CONCLUSIONS: The main finding of our study is that, compared to the BMS, implantation of the SES in aorto-ostial lesions appears safe and effective, with no increase in major in-hospital complications and a significant improvement in restenosis and late event rates at 10-month follow-up.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15337205     DOI: 10.1016/j.jacc.2004.05.058

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  7 in total

1.  Clinical impact of the gap-angle ratio in patients with ostial lesions of the right coronary artery undergoing percutaneous coronary intervention.

Authors:  Koichi Ohashi; Daisuke Abe; Norihiro Kuroki; Takao Yuba; Kou Suzuki
Journal:  Heart Vessels       Date:  2019-04-26       Impact factor: 2.037

2.  Coronary ostial stenosis after aortic valve replacement: successful treatment of 2 patients with drug-eluting stents.

Authors:  Antonios G Ziakas; Fotios I Economou; Nicholas A Charokopos; Antonios A Pitsis; Despina G Parharidou; Thomas I Papadopoulos; Georgios E Parharidis
Journal:  Tex Heart Inst J       Date:  2010

3.  Comparison of bare-metal stents and drug-eluting stents in coronary ostial lesions (from the National Heart, Lung, and Blood Institute Dynamic Registry).

Authors:  Samip Vasaiwala; Helen Vlachos; Faith Selzer; Oscar Marroquin; Suresh Mulukutla; J Dawn Abbott; David O Williams
Journal:  Am J Cardiol       Date:  2012-07-03       Impact factor: 2.778

4.  Retrospective study of treatment with a drug-coated balloon alone is beneficial for ostial coronary lesions.

Authors:  Wenduo Zhang; Fusui Ji; Xue Yu; Chenguang Yang; Xinyue Wang
Journal:  J Thorac Dis       Date:  2022-04       Impact factor: 3.005

5.  Restenosis begets restenosis: implications for stent selection.

Authors:  J S Wijpkema; R L Anthonio; G A J Jessurun; W A Dijk; R A Tio; F Zijlstra
Journal:  Neth Heart J       Date:  2008-11       Impact factor: 2.380

Review 6.  Left main coronary occlusion from Takayasu arteritis in an 8-year-old child.

Authors:  A Limsuwan; P Khowsathit; P Pienvichit
Journal:  Pediatr Cardiol       Date:  2007-03-10       Impact factor: 1.655

7.  One-year outcomes following drug-eluting balloon use for coronary ostial restenosis.

Authors:  Wei-Chieh Lee; Hsiu-Yu Fang; Wen-Jung Chung; Shu-Kai Hsueh; Chien-Jen Chen; Cheng-Hsu Yang; Hon-Kan Yip; Chi-Ling Hang; Chiung-Jen Wu; Chih-Yuan Fang
Journal:  Int J Cardiol Heart Vasc       Date:  2015-11-19