Literature DB >> 15337179

A retrospective evaluation of rigid fixation in orthognathic surgery using a biodegradable self-reinforced (70L:30DL) polylactide.

R Mazzonetto1, A O Paza, D B Spagnoli.   

Abstract

OBJECTIVE: This study was designed to evaluate clinical and radiological evidence of osteotomy site healing in orthognathic surgery after rigid fixation using a biodegradable plating system. STUDY
DESIGN: A follow up of 30 patients who underwent orthognathic surgery using a biodegradable self-reinforced (70L:30DL) polylactide plating system was presented. The follow-up schedule for all patients consisted of regular appointments at 1-180 days after surgery. Clinical evaluation involved notation of any abnormal swelling, infection, discoloration, or discharge at the osteotomy sites. Stability was evaluated by manual palpation. For radiographic evaluation, panoramic radiographs were taken immediately after surgery, and again at 7-180 days. The radiographs were analyzed for any visual changes in osteotomy fragments, resorptive changes in osteotomy fragments, callus formation, and union of the osteotomy segments.
RESULTS: No clinical complications and no radiological changes in the osteotomy sites were observed. Regarding the clinical usefulness of the biodegradable fixation system, fixation at the time of operation was considered as excellent in all 30 cases.
CONCLUSIONS: The conclusions of this study were that self-reinforced (70L:30DL) polylactide was considered to be comparable to other forms of rigid internal fixation for orthognathic surgery.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15337179     DOI: 10.1016/j.ijom.2004.02.001

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  6 in total

1.  Cost-Effectiveness of a Biodegradable Compared to a Titanium Fixation System in Maxillofacial Surgery: A Multicenter Randomized Controlled Trial.

Authors:  N B van Bakelen; K M Vermeulen; G J Buijs; J Jansma; J G A M de Visscher; Th J M Hoppenreijs; J E Bergsma; B Stegenga; R R M Bos
Journal:  PLoS One       Date:  2015-07-20       Impact factor: 3.240

Review 2.  Bioabsorbable osteofixation for orthognathic surgery.

Authors:  Young-Wook Park
Journal:  Maxillofac Plast Reconstr Surg       Date:  2015-02-19

3.  Comparison of the long-term clinical performance of a biodegradable and a titanium fixation system in maxillofacial surgery: A multicenter randomized controlled trial.

Authors:  B Gareb; N B van Bakelen; G J Buijs; J Jansma; J G A M de Visscher; Th J M Hoppenreijs; J E Bergsma; B van Minnen; B Stegenga; R R M Bos
Journal:  PLoS One       Date:  2017-05-11       Impact factor: 3.240

4.  Comparative study on long-term stability in mandibular sagittal split ramus osteotomy: hydroxyapatite/poly-l-lactide mesh versus titanium miniplate.

Authors:  Young-Wook Park; Hyun-Sik Kang; Jang-Ha Lee
Journal:  Maxillofac Plast Reconstr Surg       Date:  2019-03-01

Review 5.  A Narrative Review of u-HA/PLLA, a Bioactive Resorbable Reconstruction Material: Applications in Oral and Maxillofacial Surgery.

Authors:  Huy Xuan Ngo; Yunpeng Bai; Jingjing Sha; Shinji Ishizuka; Erina Toda; Rie Osako; Akira Kato; Reon Morioka; Mrunalini Ramanathan; Hiroto Tatsumi; Tatsuo Okui; Takahiro Kanno
Journal:  Materials (Basel)       Date:  2021-12-26       Impact factor: 3.623

6.  Is There Any Differences in Dento-Skeletal Stability between One Vs. Three-Screw Fixation of Mandible Following Bilateral Sagittal Split Osteotomy (BSSO)?

Authors:  Majid Eshghpour; Sahand Samieirad; Farzaneh MohammadZadeh Mahrokh; Niloofar EbrahimZadeh; Samine Mozaffar; Haleh Hashemzadeh
Journal:  World J Plast Surg       Date:  2022-07
  6 in total