Literature DB >> 15336350

Bead injection spectroscopy-flow injection analysis (BIS-FIA): an interesting tool applicable to pharmaceutical analysis. Determination of promethazine and trifluoperazine.

M J Ruedas Rama1, A Ruiz Medina, A Molina Díaz.   

Abstract

A bead injection spectroscopy-flow injection analysis (BIS-FIA) system for the spectrophotometric detection of promethazine and trifluoperazine is developed. The sensor is based in the oxidation of the phenothiazines by Fe(III) which is later determined by formation of the complex between Fe(II) and Ferrozine, [FeFz(3)](4-). Immediately, this complex is retained on a homogeneous bead suspension of Sephadex QAE A-25 resin (500 microl) which has been injected previously in the system to fill a commercial flow-cell (Hellma 138-OS). The use of BI with respect to the use of a reusable flow-through sensor is justified because the complex is so strongly retained on the beads that the regeneration of the solid support becomes extraordinarily difficult in the proposed method. At the end of the analysis, beads are automatically discarded from the flow-cell, by reversing the flow, and transported out of the system. The analytical signals are measured at a wavelength of 567 nm, corresponding to the absorbance of the complex. Using a sample volume of 600 microl, the analytical signal showed a very good linearity in the range 0.5-8.0 microgml(-1) and 0.5-10.0 microgml(-1), with detection limits of 0.09 and 0.14 microgml(-1) for promethazine and trifluoperazine, respectively. R.S.D.s (%) lower than 2% were obtained for both analytes. The proposed method is highly selective in the presence of other species that are normally encountered with these analytes. The sensor was satisfactorily applied to pharmaceutical preparations.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15336350     DOI: 10.1016/j.jpba.2004.03.010

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  5 in total

1.  Simultaneous RP-HPLC Estimation of Trifluoperazine Hydrochloride and Chlordiazepoxide in Tablet Dosage Forms.

Authors:  Sejal K Patel; N J Patel
Journal:  Indian J Pharm Sci       Date:  2009-09       Impact factor: 0.975

2.  Portable system of programmable syringe pump with potentiometer for determination of promethazine in pharmaceutical applications.

Authors:  Tawfik A Saleh; A M Abulkibash; Atta E Ibrahim
Journal:  Saudi Pharm J       Date:  2011-09-03       Impact factor: 4.330

3.  Ionophore-based potentiometric sensors for the flow-injection determination of promethazine hydrochloride in pharmaceutical formulations and human urine.

Authors:  Ahmed Khudhair Hassan; Bahruddin Saad; Sulaiman Ab Ghani; Rohana Adnan; Afidah Abdul Rahim; Norariza Ahmad; Marina Mokhtar; Suham Tawfiq Ameen; Suad Mustafa Al-Araji
Journal:  Sensors (Basel)       Date:  2011-01-18       Impact factor: 3.576

Review 4.  State-of-the-art of (bio)chemical sensor developments in analytical Spanish groups.

Authors:  María Reyes Plata; Ana María Contento; Angel Ríos
Journal:  Sensors (Basel)       Date:  2010-03-24       Impact factor: 3.576

5.  Analytical Applications of Reactions of Iron(III) and Hexacyanoferrate(III) with 2,10-Disubstituted Phenothiazines.

Authors:  Helena Puzanowska-Tarasiewicz; Joanna Karpińska; Ludmiła Kuźmicka
Journal:  Int J Anal Chem       Date:  2009-02-02       Impact factor: 1.885

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.