Literature DB >> 15334755

Plateletworks platelet function test compared to the thromboelastograph for prediction of postoperative outcomes.

Jacob Ostrowsky1, Jennifer Foes, Mark Warchol, Gary Tsarovsky, Jessica Blay.   

Abstract

Approximately 3.5 million units of platelets are transfused in the United States each year to patients undergoing open-heart surgery with cardiopulmonary bypass (CPB). CPB is a known contributor to platelet loss and platelet dysfunction leading to disruption of hemostasis. Impaired hemostasis results in excess bleeding in 5-25% of all patients undergoing CPB. For this reason, it may be beneficial to measure platelet number and function in these patients. The purpose of this study was to compare the Plateletworks platelet function analyzer to the thromboelastograph (TEG) in predicting postoperatiave hemostatic outcomes as measured by blood product use and chest tube (CT) drainage. This study consisted of 35 adult patients undergoing cardiac surgery with cardiopulmonary bypass at Rush-Presbyterian-Saint Luke's Medical Center (RPSLMC). The Plateletworks and TEG tests were performed preoperatively, after protamine was given, and 24 hours postoperatively on all patients. Plateletworks demonstrated a statistically significant change in platelet function as shown by the adenosine diphosphate (ADP) reagent tube from the preoperative period to the removal of the aortic cross clamp (p = .011). The TEG did not demonstrate a significant change in the k-time and maximum amplitude (MA), but did show a significant change in the alpha-angle from the pre-operative to postoperatiave sample (p = .035). A correlation was found between Plateletworks collagen reagent tubes preoperatively and CT drainage (p = .048, r -0.324). No statistical correlation was established between TEG parameters and CT drainage at any time interval. TEG preoperative MA showed a correlation to receipt of blood products (p = .016). When comparing the Plateletworks to the TEG in this study, the Plateletworks system was a more useful predictor of blood product use and chest tube drainage.

Entities:  

Mesh:

Year:  2004        PMID: 15334755

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  3 in total

1.  The Role of Platelet Function Analyzer Testing in Cardiac Surgery Transfusion Management.

Authors:  Dejana Bogdanic; Nenad Karanovic; Jela Mratinovic-Mikulandra; Branka Paukovic-Sekulic; Dijana Brnic; Ivanka Marinovic; Diana Nonkovic; Nikolina Bogdanic
Journal:  Transfus Med Hemother       Date:  2017-02-01       Impact factor: 3.747

Review 2.  Thromboelastography and rotational thromboelastometry for the surgical intensivist: A narrative review.

Authors:  Byron C Drumheller; Deborah M Stein; Laura J Moore; Sandro B Rizoli; Mitchell J Cohen
Journal:  J Trauma Acute Care Surg       Date:  2019-04       Impact factor: 3.313

3.  Bleeding risk assessment using whole blood impedance aggregometry and rotational thromboelastometry in patients following cardiac surgery.

Authors:  Mate Petricevic; Bojan Biocina; Davor Milicic; Sanja Konosic; Lucija Svetina; Ante Lekić; Boris Zdilar; Ivan Burcar; Milan Milosevic; Rifat Brahimaj; Jure Samardzic; Hrvoje Gasparovic
Journal:  J Thromb Thrombolysis       Date:  2013-11       Impact factor: 2.300

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.