Literature DB >> 15334593

Self-calibrated spiral SENSE.

Yongxian Qian1, Zhenghui Zhang, V Andrew Stenger, Yi Wang.   

Abstract

Current standard sensitivity-encoded parallel imaging (SENSE) utilizes a fully sampled low-resolution reference scan to estimate the coil sensitivities. This reference scan adds scan time and may introduce misregistration artifacts. The purpose of this study was to investigate the feasibility of estimating the coil sensitivities for spiral SENSE directly from an undersampled k-space center. The limited spatial frequencies of the coil sensitivities, and the undersampling beyond the Nyquist radius cause image artifacts. A point spread function (PSF) analysis and experiments on both phantoms and humans identified an optimal radius for the k-space center by minimizing these image artifacts. The preliminary data indicate that self-calibrated SENSE is as accurate as standard SENSE, which uses a fully sampled reference scan. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 15334593     DOI: 10.1002/mrm.20197

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  A radial self-calibrated (RASCAL) generalized autocalibrating partially parallel acquisition (GRAPPA) method using weight interpolation.

Authors:  Noel C F Codella; Pascal Spincemaille; Martin Prince; Yi Wang
Journal:  NMR Biomed       Date:  2010-12-28       Impact factor: 4.044

2.  Improved self-calibrated spiral parallel imaging using JSENSE.

Authors:  Jinhua Sheng; Erik Wiener; Bo Liu; Fernando Boada; Leslie Ying
Journal:  Med Eng Phys       Date:  2008-11-21       Impact factor: 2.242

3.  Fast parallel spiral chemical shift imaging at 3T using iterative SENSE reconstruction.

Authors:  Dirk Mayer; Dong-Hyun Kim; Daniel M Spielman; Roland Bammer
Journal:  Magn Reson Med       Date:  2008-04       Impact factor: 4.668

4.  Augmented Lagrangian with variable splitting for faster non-Cartesian L1-SPIRiT MR image reconstruction.

Authors:  Daniel S Weller; Sathish Ramani; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2013-10-09       Impact factor: 10.048

5.  Interleaved spiral-in/out with application to functional MRI (fMRI).

Authors:  Christine S Law; Gary H Glover
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

6.  A 3 T sodium and proton composite array breast coil.

Authors:  Joshua D Kaggie; J Rock Hadley; James Badal; John R Campbell; Daniel J Park; Dennis L Parker; Glen Morrell; Rexford D Newbould; Ali F Wood; Neal K Bangerter
Journal:  Magn Reson Med       Date:  2013-09-16       Impact factor: 4.668

7.  Parallel spectroscopic imaging reconstruction with arbitrary trajectories using k-space sparse matrices.

Authors:  Meng Gu; Chunlei Liu; Daniel M Spielman
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

8.  Rapid flow assessment of congenital heart disease with high-spatiotemporal-resolution gated spiral phase-contrast MR imaging.

Authors:  Jennifer A Steeden; David Atkinson; Michael S Hansen; Andrew M Taylor; Vivek Muthurangu
Journal:  Radiology       Date:  2011-03-17       Impact factor: 11.105

9.  Spiral Perfusion Imaging With Consecutive Echoes (SPICE™) for the Simultaneous Mapping of DSC- and DCE-MRI Parameters in Brain Tumor Patients: Theory and Initial Feasibility.

Authors:  Eric S Paulson; Douglas E Prah; Kathleen M Schmainda
Journal:  Tomography       Date:  2016-12
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.