Literature DB >> 15334560

In vivo study of microbubbles as an MR susceptibility contrast agent.

Kelvin K Wong1, Ingjye Huang, Young R Kim, Haiying Tang, Edward S Yang, Kenneth K Kwong, Ed X Wu.   

Abstract

The potential application of gas microbubbles as a unique intravascular susceptibility contrast agent for MRI has not been fully explored. In this study, the MR susceptibility effect of an ultrasound microbubble contrast agent, Optison, was studied with rat liver imaging at 7 T. Optison suspension in two different doses (0.15 mL/kg and 0.4 mL/kg) was injected into rats, and induced transverse relaxation rate increases (deltaR2*) of 29.1 +/- 1.6 s(-1) (N = 2) and 61.5 +/- 12.9 s(-1) (N = 6), respectively, in liver tissue. Liver uptake of intact albumin microbubbles was observed 10 min after injection. Eight of the 16 rats studied showed no susceptibility enhancement. This is probably attributable to the intravascular microbubble growth due to transmural CO2 supersaturation in the cecum and colon in small animals that causes microbubble aggregation and trapping in the inferior vena cava (IVC). In vitro deltaR2* measurements of Optison suspension at different concentrations are also reported. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15334560     DOI: 10.1002/mrm.20181

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Signal decay due to susceptibility-induced intravoxel dephasing on multiple air-filled cylinders: MRI simulations and experiments.

Authors:  François De Guio; Hugues Benoit-Cattin; Armel Davenel
Journal:  MAGMA       Date:  2008-06-25       Impact factor: 2.310

2.  Theranostic Gd(III)-lipid microbubbles for MRI-guided focused ultrasound surgery.

Authors:  Jameel A Feshitan; Fotis Vlachos; Shashank R Sirsi; Elisa E Konofagou; Mark A Borden
Journal:  Biomaterials       Date:  2011-10-10       Impact factor: 12.479

3.  Microbubbles in Imaging: Applications Beyond Ultrasound.

Authors:  Paul Kogan; Ryan C Gessner; Paul A Dayton
Journal:  Bubble Sci Eng Technol       Date:  2010-06

4.  Evaluation of microbubbles as contrast agents for ultrasonography and magnetic resonance imaging.

Authors:  Ling Li; Qiang Wei; Hong-Bo Li; Song Wen; Gao-Jun Teng
Journal:  PLoS One       Date:  2012-04-10       Impact factor: 3.240

5.  Applications of magnetic microbubbles for theranostics.

Authors:  Xiaowei Cai; Fang Yang; Ning Gu
Journal:  Theranostics       Date:  2012-01-12       Impact factor: 11.556

Review 6.  Ultrasound-targeted microbubble destruction for chemotherapeutic drug delivery to solid tumors.

Authors:  Hong Chen; Joo Ha Hwang
Journal:  J Ther Ultrasound       Date:  2013-07-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.