Literature DB >> 1533448

Comparative tissue tolerance of a new endodontic sealer.

D Molloy1, M Goldman, R R White, S Kabani.   

Abstract

An experimental radiopaque resin root canal sealer was tested for tissue biocompatibility in rat connective tissue. The controls were four widely used sealers: Sealapex, Kerr's sealer, AH-26, and Roth's sealer. Polyethylene tubes were filled with the sealers and allowed to set for 24 hours in 100% humidity. Each sealer was implanted in the connective tissue of Sprague-Dawley rats and removed after 3, 10, 20, 30, and 60 days, fixed, and histologically prepared for light microscope evaluation. At each time period there was practically no difference in the reaction of all the sealers. By 60 days, the total picture was one of well-tolerated biocompatibility.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1533448     DOI: 10.1016/0030-4220(92)90332-k

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol        ISSN: 0030-4220


  2 in total

1.  Biocompatibility of RealSeal, its primer and AH Plus implanted in subcutaneous connective tissue of rats.

Authors:  Fabiana Soares Grecca; Patrícia Maria Poli Kopper; Régis Burmeister dos Santos; Anna Christina Fossati; Vinicius Coelho Carrard; Gerson Arison Xavier Acasigua; José Antônio Poli de Figueiredo
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

2.  Subcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model.

Authors:  Salma Omidi; Maryam Javidi; Mina Zarei; Siavash Mushakhian; Amirhossein Jafarian
Journal:  Iran Endod J       Date:  2017
  2 in total