Literature DB >> 15332188

Navigation surgery for dental implants: assessment of accuracy of the image guided implantology system.

Nardy Casap1, Alon Wexler, Nathan Persky, Amir Schneider, Joshua Lustmann.   

Abstract

PURPOSE: The purpose of this study is to assess the accuracy of the navigation provided by the Image Guided Implantology system (DenX Advanced Dental Systems, Moshav Ora, Israel), which was designed to guide the surgeon in the placement of dental implants.
MATERIALS AND METHODS: Seven jaw models incorporating special ceramic spheres were imaged by dental computerized tomography. The coordinates of these reference ceramic markers were calculated by the Image Guided Implantology and compared with their actual position coordinates as identified on the computed tomography image.
RESULTS: The overall mean spatial navigation error was 0.35 +/- 0.14 mm. The 1-tailed probability of any single measurement exceeding 0.75 mm was less than 0.003, and that exceeding 1 mm was less than 0.0001.
CONCLUSION: The Image Guided Implantology system provides highly accurate navigation with less than 0.73 mm error, which is acceptable in dental implantology. The accurate reporting of the exact position of the drilling bur should minimize the potential risk of damage to critical anatomic structures. The accurate intraoperative navigation allows the surgeon to precisely transfer the presurgical plan to the patient.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15332188     DOI: 10.1016/j.joms.2004.06.028

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  7 in total

1.  Bone treatment laser-navigated surgery.

Authors:  Bettina Hohlweg-Majert; Herbert Deppe; Marc C Metzger; Sebstian Stopp; Klaus-Dietrich Wolff; Tim C Lueth
Journal:  Lasers Med Sci       Date:  2009-03-11       Impact factor: 3.161

2.  The Challenge of Dental Education After COVID-19 Pandemic - Present and Future Innovation Study Design.

Authors:  Miguel Pais Clemente; André Moreira; João Correia Pinto; José Manuel Amarante; Joaquim Mendes
Journal:  Inquiry       Date:  2021 Jan-Dec       Impact factor: 1.730

3.  Image-guided surgery and medical robotics in the cranial area.

Authors:  G Widmann
Journal:  Biomed Imaging Interv J       Date:  2007-01-01

Review 4.  Computerized implant-dentistry: Advances toward automation.

Authors:  Minkle Gulati; Vishal Anand; Sanjeev Kumar Salaria; Nikil Jain; Shilpi Gupta
Journal:  J Indian Soc Periodontol       Date:  2015 Jan-Feb

5.  The influence of cone beam computed tomography on IRIS-100 implant navigation system.

Authors:  Pei-Ling Lai; Meng-Chen Lee; Chih-Te Liu; Po-Sung Fu; Ting-Hsun Lan; Jen-Chyan Wang; Chun-Cheng Hung
Journal:  J Dent Sci       Date:  2022-05-11       Impact factor: 3.719

6.  Accuracy of intraoral real-time navigation versus static, CAD/CAM-manufactured pilot drilling guides in dental implant surgery: an in vitro study.

Authors:  Robert Stünkel; Alexander-Nicolai Zeller; Thomas Bohne; Florian Böhrnsen; Edris Wedi; David Raschke; Philipp Kauffmann
Journal:  Int J Implant Dent       Date:  2022-10-06

7.  Surgical Navigation, Augmented Reality, and 3D Printing for Hard Palate Adenoid Cystic Carcinoma En-Bloc Resection: Case Report and Literature Review.

Authors:  Mónica García-Sevilla; Rafael Moreta-Martinez; David García-Mato; Gema Arenas de Frutos; Santiago Ochandiano; Carlos Navarro-Cuéllar; Guillermo Sanjuán de Moreta; Javier Pascau
Journal:  Front Oncol       Date:  2022-01-04       Impact factor: 6.244

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.