UNLABELLED: A study was performed in a call center that provides billing inquiry services using a 2 x 2 balanced experimental plan for nine consecutive weeks. Two independent variables, temperature and outdoor air supply rate, were combined and introduced to the occupants in a blind intervention approach. The temperature set-points were fixed at 22.5 degrees C and 24.5 degrees C, and outdoor air supply rate at 5 l /s/p and 10 l/s/p. Temperature and outdoor air supply rate had significant interaction effects on worker's talk time (P < 0.001), which means that the effects of temperature on talk time performance were not independent of the effects of outdoor air supply rate or the opposite. Talk time was reduced significantly when the outdoor air supply rate was increased from 5 l /s/p to 10 l/s/p at 24.5 degrees C (P < 0.01); this may be associated with the significant reduction in a principal component factor which includes intensity of dryness, aching eyes and nose-related symptoms (P < 0.01). Decreasing the temperature from 24.5 degrees C to 22.5 degrees C at 10 l /s/p significantly increased talk time (P < 0.01). Analysis of the principal component factor based on the neurobehavioral symptoms also revealed that temperature reduction led to an increased mean factor score of these symptoms (P < 0.04). PRACTICAL IMPLICATIONS: For moderately complex office work which involves manipulation dexterity such as a call center operation where call operators interact with computer-based information systems, tropically acclimatized workers' performance could be improved by increasing the outdoor air supply rate from 5 l/s/p to 10 l/s/p if the temperature is to be maintained at the higher band of the thermal comfort range, around 24.5 degrees C. At a low ventilation rate (5 l/s/p), decreasing the temperature from 24.5 degrees C to 22.5 degrees C (which is a commonly adopted set-point in tropical office buildings) also leads to improvement of talk time performance. The magnitude of talk time improvement was greater by more than four times when the strategy to increase the outdoor air supply rate was implemented at a lower range of outdoor air supply rate (5-10 l /s/p) as compared to the higher range (9.8-22.7 l/s/p).

Mesh:

Year:  2004        PMID: 15330779     DOI: 10.1111/j.1600-0668.2004.00280.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  2 in total

1.  Energy and cost associated with ventilating office buildings in a tropical climate.

Authors:  Donghyun Rim; Stefano Schiavon; William W Nazaroff
Journal:  PLoS One       Date:  2015-03-30       Impact factor: 3.240

2.  Impact of Indoor Physical Environment on Learning Efficiency in Different Types of Tasks: A 3 × 4 × 3 Full Factorial Design Analysis.

Authors:  Lilin Xiong; Xiao Huang; Jie Li; Peng Mao; Xiang Wang; Rubing Wang; Meng Tang
Journal:  Int J Environ Res Public Health       Date:  2018-06-13       Impact factor: 3.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.