Literature DB >> 15330047

A novel crosslinkable polymer as drug-loaded coating for biomedical device.

Jian-Ping Xu1, Jian Ji, Wei-Dong Chen, Hui-Fang Zhao, Jia-Cong Shen, De-Zeng Fan, Yu-Fu Sun.   

Abstract

A novel copolymer has been synthesized by the radical polymerization of poly (ethylene oxide) methacrylate, stearyl methacrylate, hydroxypropyl methacrylate and trimethoxysilylpropyl methacrylate. The polymer was characterized by Fourier transform infrared spectroscopy, proton nuclear magnetic resonance (1H-NMR) spectroscopy and gel permeation chromatography. The crosslinkable coating was prepared by dip-coating 5mg/ml solution in tetrahydrofuran onto glass substrate. A stable crosslinked coating was obtained after curing the coating at 70 degrees C for 9 h. Contact angle results indicated the possible reorganization of the surface amphiphilic molecule which interpreted the excellent biocompatibility revealed by the results of the platelet adhesion and plasma recalcification time. Rhodamine S and Cibacron Blue were used as model drugs to prepare drug-containing coating at the same conditions. Drug-releasing curves indicated that the mechanism of the release is approximately Fickian release.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15330047     DOI: 10.1023/b:jmsm.0000011814.05438.12

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  6 in total

1.  Poly(2-hydroxyethyl methacrylate) film as a drug delivery system for pilocarpine.

Authors:  G H Hsiue; J A Guu; C C Cheng
Journal:  Biomaterials       Date:  2001-07       Impact factor: 12.479

2.  Surface coating of stearyl poly(ethylene oxide) coupling-polymer on polyurethane guiding catheters with poly(ether urethane) film-building additive for biomedical applications.

Authors:  D A Wang; J Ji; C Y Gao; G H Yu; L X Feng
Journal:  Biomaterials       Date:  2001-06       Impact factor: 12.479

3.  Using hydrogel polymers for drug delivery.

Authors:  A M McNair
Journal:  Med Device Technol       Date:  1996-12

Review 4.  Does polyethylene oxide possess a low thrombogenicity?

Authors:  G R Llanos; M V Sefton
Journal:  J Biomater Sci Polym Ed       Date:  1993       Impact factor: 3.517

5.  Stent-based delivery of sirolimus reduces neointimal formation in a porcine coronary model.

Authors:  T Suzuki; G Kopia; S Hayashi ; L R Bailey; G Llanos; R Wilensky; B D Klugherz; G Papandreou; P Narayan; M B Leon; A C Yeung; F Tio; P S Tsao; R Falotico; A J Carter
Journal:  Circulation       Date:  2001-09-04       Impact factor: 29.690

6.  Surface molecular mobility and platelet reactivity of segmented poly(etherurethaneureas) with hydrophilic and hydrophobic soft segment components.

Authors:  A Takahara; N J Jo; T Kajiyama
Journal:  J Biomater Sci Polym Ed       Date:  1989       Impact factor: 3.517

  6 in total
  1 in total

1.  Antibacterial Activity of Antibiotic-Releasing Polydopamine-Coated Nephrite Composites for Application in Drug-Eluting Contact Lens.

Authors:  Min-Seung Kang; Kyung-Jin Moon; Ji-Eun Lee; Young-Il Jeong
Journal:  Materials (Basel)       Date:  2022-07-11       Impact factor: 3.748

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.