Literature DB >> 15330027

Stability of cemented all-polyethylene keeled glenoid components. A radiostereometric study with a two-year follow-up.

H Rahme1, P Mattsson, S Larsson.   

Abstract

We studied the stability of cemented all-polyethylene keeled glenoid components by radiostereometric analysis (RSA) in 16 shoulders which had received a total shoulder replacement. There were 14 women (one bilateral) and one man with a mean age of 64 years. The diagnosis was osteoarthritis in eight and rheumatoid arthritis in seven. Two of the shoulders were excluded from the RSA study because of loosening of the tantalum markers. Three tantalum markers were inserted in the glenoid socket, two in the coracoid process and two in the acromion. The polyethylene keeled glenoid component was marked with three to five tantalum markers. Conventional radiological and RSA examinations were carried out at five to seven days, at four months and at one and two years after operation. Radiolucent lines were found in all except three shoulders. Migration was most pronounced in the distal direction and exceeded 1 mm in four shoulders. In ten shoulders rotation exceeded 2 degrees in one or more axes with retroversion/anteversion being most common. No correlation was found between migration and the presence of radiolucencies on conventional radiographs.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15330027     DOI: 10.1302/0301-620x.86b6.14882

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  6 in total

1.  Long-term survival of the glenoid components in total shoulder replacement for arthritis.

Authors:  Dominique F Gazielly; Marius M Scarlat; Olivier Verborgt
Journal:  Int Orthop       Date:  2014-12-24       Impact factor: 3.075

2.  Radiostereometric analysis of keeled versus pegged glenoid components in total shoulder arthroplasty: a randomized feasibility study.

Authors:  Trevor C Gascoyne; Sheila M B McRae; Sara L Parashin; Jeff R S Leiter; Martin J Petrak; Eric R Bohm; Peter B MacDonald
Journal:  Can J Surg       Date:  2017-08       Impact factor: 2.089

3.  Shoulder Arthroplasty for Humeral Head Avascular Necrosis Is Associated With Increased Postoperative Complications.

Authors:  M Tyrrell Burrus; Jourdan M Cancienne; Jeffrey D Boatright; Scott Yang; Stephen F Brockmeier; Brian C Werner
Journal:  HSS J       Date:  2017-05-15

4.  Differentially loaded radiostereometric analysis to monitor fracture stiffness: a feasibility study.

Authors:  Mellick J Chehade; Lucian B Solomon; Stuart A Callary; Sam H Benveniste; Anthony P Pohl; Donald W Howie
Journal:  Clin Orthop Relat Res       Date:  2009-01-29       Impact factor: 4.176

Review 5.  The accuracy and precision of radiostereometric analysis in upper limb arthroplasty.

Authors:  Bart Ten Brinke; Annechien Beumer; Koen L M Koenraadt; Denise Eygendaal; Gerald A Kraan; Nina M C Mathijssen
Journal:  Acta Orthop       Date:  2017-03-02       Impact factor: 3.717

6.  Stable glenoid component of reverse total shoulder arthroplasty at 2 years as measured with model-based radiostereometric analysis (RSA).

Authors:  Alexander Nilsskog Fraser; Berte Bøe; Tore Fjalestad; Jan Erik Madsen; Stephan M Röhrl
Journal:  Acta Orthop       Date:  2021-07-01       Impact factor: 3.717

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.