Literature DB >> 15329760

Integrated hydroxyapatite implant and non-integrated implants in enucleated Asian patients.

C T Chuah1, S P Chee, K S Fong, Y M Por, C T Choo, C Luu, L L Seah.   

Abstract

INTRODUCTION: This study compares the outcome and complications of integrated hydroxyapatite implant and non-integrated orbital implants following enucleation in Asian patients.
MATERIALS AND METHODS: This is a retrospective study of enucleated patients with coralline hydroxyapatite implants versus non-integrated implants (acrylic, glass and silicone) at the Singapore National Eye Centre from January 1991 to December 2000. The outcomes measured were implant migration, extrusion, socket infection, conjunctival dehiscence and implant exposure. Statistical analysis was done using the 2-sample t-test.
RESULTS: Twenty-one patients had the hydroxyapatite implant and 38 non-integrated implants (27 acrylic, 9 glass and 2 silicone). The mean duration of follow-up was 2.7 years and 4 years for the hydroxyapatite implant and non-integrated implants respectively. Three patients with pre-existing severe socket contracture before enucleation surgeries were excluded from the study. Four cases of implant migration, 4 cases of implant extrusion and 3 cases of socket infection were encountered; all were sockets fitted with non-integrated implants. There was a higher rate of conjunctival dehiscence for sockets with hydroxyapatite implants (6 out of 21) compared to sockets with non-integrated implants (3 out of 35). This was statistically significant (P = 0.048).
CONCLUSIONS: Implant complications of migration, extrusion and socket infection were found in non-integrated implants and none in coralline hydroxyapatite implants, which had a significantly higher rate of conjunctival dehiscence. Most of these were easily managed with only a small number progressing to implant exposure.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15329760

Source DB:  PubMed          Journal:  Ann Acad Med Singapore        ISSN: 0304-4602            Impact factor:   2.473


  5 in total

Review 1.  Ocular prosthesis incorporating IPS e-max press scleral veneer and a literature review on non-integrated ocular prosthesis.

Authors:  Godwin Clovis Da Costa; Meena Ajay Aras; Paul Chalakkal; Michelle Clovis Da Costa
Journal:  Int J Ophthalmol       Date:  2017-01-18       Impact factor: 1.779

2.  A simplified technique for fabrication of orbital prosthesis.

Authors:  Neeraj Sharma; G K Thakral; Abhilash Mohapatra; Jyotsna Seth; Pallavi Vashisht
Journal:  J Clin Diagn Res       Date:  2014-06-20

Review 3.  Integrated versus non-integrated orbital implants for treating anophthalmic sockets.

Authors:  Silvana Schellini; Regina El Dib; Leandro Re Silva; Joyce G Farat; Yuqing Zhang; Eliane C Jorge
Journal:  Cochrane Database Syst Rev       Date:  2016-11-07

4.  Enucleation in malignant choroidal melanoma - results in 15 years of using a new material in the prosthesis of the orbital cavity.

Authors:  C P Tataru; M D Pop
Journal:  J Med Life       Date:  2012-06-18

5.  Complications of orbital endoimplantation in the Eye Clinic of the Lithuanian University of Health Sciences.

Authors:  Raimonda Piškinienė; Mantas Banevičius
Journal:  Acta Med Litu       Date:  2017
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.