Literature DB >> 15329316

Fasting plasma glucose versus glucose challenge test: screening for gestational diabetes and cost effectiveness.

Evelyne Rey1, Linda Hudon, Nicole Michon, Pauline Boucher, Johanne Ethier, Patrick Saint-Louis.   

Abstract

OBJECTIVE: To compare the performance in screening for gestational carbohydrate intolerance of the 1-h 50-g glucose challenge test (GCT), fasting plasma glucose (FPG) and fasting capillary glucose (FCG). DESIGN AND METHODS: FPG and FCG were measured at the same time as the GCT in 188 women. Gestational carbohydrate intolerance was diagnosed according to the Canadian Diabetes Association criteria. We constructed receiver operator characteristic (ROC) curves and compared the sensitivity and specificity of the FPG, FCG and GCT.
RESULTS: Gestational diabetes was diagnosed in 11.2% women and gestational impaired glucose tolerance in 8.4%. The areas under the ROC curves for the FPG, the GCT and the FCG were not statistically different (P = 0.26). The GCT yielded a better specificity than the FPG and the FCG for a comparable level of sensitivity.
CONCLUSIONS: The GCT is better than the FPG in our population and is cost effective.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15329316     DOI: 10.1016/j.clinbiochem.2004.05.018

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  5 in total

1.  Gestational diabetes mellitus: Screening with fasting plasma glucose.

Authors:  Mukesh M Agarwal
Journal:  World J Diabetes       Date:  2016-07-25

2.  Paired values of serum fructosamine and blood glucose for the screening of gestational diabetes mellitus: A retrospective study of 165 Saudi pregnant women.

Authors:  Haseeb Ahmad Khan; Samia Hasan Sobki; Abdullah Saleh Alhomida; Shaukat Ali Khan
Journal:  Indian J Clin Biochem       Date:  2007-03

Review 3.  The urgent need for universally applicable simple screening procedures and diagnostic criteria for gestational diabetes mellitus--lessons from projects funded by the World Diabetes Foundation.

Authors:  Karoline Kragelund Nielsen; Maximilian de Courten; Anil Kapur
Journal:  Glob Health Action       Date:  2012-07-30       Impact factor: 2.640

4.  How high is too high in cutoff levels from 50-g glucose challenge test.

Authors:  Hyun-Hwa Cha; Ji Ye Kim; Suk-Joo Choi; Soo-Young Oh; Cheong-Rae Roh; Jong-Hwa Kim
Journal:  Obstet Gynecol Sci       Date:  2016-05-13

5.  Accuracy of screening tests for gestational diabetes mellitus in Southeast Asia: A systematic review of diagnostic test accuracy studies.

Authors:  Sattamat Lappharat; Tippawan Liabsuetrakul
Journal:  Medicine (Baltimore)       Date:  2020-11-13       Impact factor: 1.817

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.