Literature DB >> 15325925

Results of catheter ablation of typical atrial flutter.

Hugh Calkins1, Robert Canby, Raul Weiss, Gregg Taylor, Peter Wells, Larry Chinitz, Simon Milstein, Steven Compton, Kimberly Oleson, Lou Sherfesee, John Onufer.   

Abstract

The purpose of this study was to evaluate the safety and efficacy of radiofrequency (RF) ablation of typical atrial flutter by using an 8-mm electrode catheter and a 100-W RF power generator. A limitation of previous trials of catheter ablation of atrial flutter is that the data were not collected as part of a prospective multicenter clinical trial. The study results associated catheter ablation of typical atrial flutter in a cohort of 150 patients with an 88% acute efficacy rate. At 6-month follow-up, recurrent typical atrial flutter was observed in 13% of patients. Of the 12 patients with typical atrial flutter recurrence, 4 were symptomatic and 8 were asymptomatic. Procedure duration was a significant predictor of typical atrial flutter recurrence. The 12-month rate for development of atrial fibrillation was 30%. Catheter ablation of atrial flutter was associated with significant improvements in 5 of 8 domains of the Short Form 36 Survey (quality of life) and significant decreases in 13 of the 16 symptoms of the Symptom Checklist. The device- or procedure-related complication rate was 2.7%. Skin burns occurred at the dispersive pad site due to stronger RF power in 3 patients. Use of a dual dispersive pad system mitigated this problem. Thus, the results of this study associated catheter ablation of atrial flutter with high acute efficacy, a small risk of recurrent atrial flutter, and an important risk of atrial fibrillation during follow-up.

Entities:  

Mesh:

Year:  2004        PMID: 15325925     DOI: 10.1016/j.amjcard.2004.04.058

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  17 in total

1.  The roles of anatomy, image, and electrogram voltage in ablation of cavotricuspid isthmus.

Authors:  Shih-Ann Chen; Satoshi Higa
Journal:  J Interv Card Electrophysiol       Date:  2005-01       Impact factor: 1.900

2.  Success rate of catheter ablation in atrial flutter: comparison of a 4- or 5-mm tip electrode catheter with an 8-mm tip electrode catheter.

Authors:  Sucheta Gosavi; Greg Flaker
Journal:  J Interv Card Electrophysiol       Date:  2006-10-11       Impact factor: 1.900

Review 3.  Initial description of radiofrequency catheter ablation as treatment for atrial flutter in Marfan's syndrome: a case report and literature review.

Authors:  Ahmad Halawa; Vipul Brahmbhatt; Stephen A Fahrig
Journal:  J Interv Card Electrophysiol       Date:  2007-06-28       Impact factor: 1.900

4.  Quality of life and occurrence of atrial fibrillation in long-term follow-up of common type atrial flutter ablation: ablation with irrigated 5 mm tip and conventional 8 mm tip electrodes.

Authors:  Axel Meissner; Martin Christ; Petra Maagh; Rolf Borchard; Marc van Bracht; Ingo Wickenbrock; Hans-Joachim Trappe; Gunnar Plehn
Journal:  Clin Res Cardiol       Date:  2007-08-31       Impact factor: 5.460

5.  A prospective randomised comparison of large-tip cryoablation and 8-mm-tip radiofrequency catheter ablation of atrial flutter.

Authors:  Helena Malmborg; Stefan Lönnerholm; Carina Blomström Lundqvist
Journal:  J Interv Card Electrophysiol       Date:  2008-11-06       Impact factor: 1.900

6.  Frequency of atrial arrhythmias after atrial flutter ablation and the effect of presenting rhythm on the day of ablation.

Authors:  Anupama Vasudevan; Aneley Hundae; Darara Borodge; Peter A McCullough; Peter J Wells
Journal:  Proc (Bayl Univ Med Cent)       Date:  2018-05-14

Review 7.  [Catheter ablation of typical atrial flutter].

Authors:  Hansjörg Bauerle; T Japha; B-D Gonska
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-07-13

8.  Interactive real-time mapping and catheter ablation of the cavotricuspid isthmus guided by magnetic resonance imaging in a porcine model.

Authors:  Boris A Hoffmann; Andreas Koops; Thomas Rostock; Kai Müllerleile; Daniel Steven; Roman Karst; Mark U Steinke; Imke Drewitz; Gunnar Lund; Susan Koops; Gerhard Adam; Stephan Willems
Journal:  Eur Heart J       Date:  2009-11-05       Impact factor: 29.983

9.  Health-related quality of life in different clinical subgroups with typical AFL who have undergone cavo-tricuspid isthmus ablation.

Authors:  Javier García Seara; Francisco Gude; Pilar Cabanas; José L Martínez-Sande; Xesús Fernández López; Antonio Hernández Madrid; Concepción Moro; José R González Juanatey
Journal:  Health Qual Life Outcomes       Date:  2012-08-06       Impact factor: 3.186

10.  Acute success and short-term follow-up of catheter ablation of isthmus-dependent atrial flutter; a comparison of 8 mm tip radiofrequency and cryothermy catheters.

Authors:  A S Thornton; P Janse; M Alings; M F Scholten; J M Mekel; M Miltenburg; E Jessurun; L Jordaens
Journal:  J Interv Card Electrophysiol       Date:  2008-03-25       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.