Literature DB >> 15324356

Critical steps in electronic volume quantification of gingival crevicular fluid: the potential impact of evaporation, fluid retention, local conditions and repeated measurements.

Tolga F Tözüm1, Hasan Hatipoğlu, Nermin Yamalik, Mihtikar Gürsel, Nilgün O Alptekin, Tamer Ataoğlu, Ismail Marakoğlu, Ulvi K Gürsoy, Kenan Eratalay.   

Abstract

BACKGROUND AND OBJECTIVES: Various methodological factors may operate during clinical gingival crevicular fluid (GCF) sampling, volume quantification or subsequent laboratory analysis. For precise volume quantification, specific concern for generation and maintenance of a reliable calibration curve, the potential risk of GCF loss as a result of evaporation or fluid retention on actual volume and the impact of local conditions is needed because each of these factors may act as a source of subsequent volumetric distortions. Thus, the present study aimed to analyse the impact of sample transfer time on the rate of evaporation and the possibility of fluid retention, and the impact of local conditions and number of replicated measurements on the reliability of calibration data.
MATERIALS AND METHODS: To analyse evaporative errors, standardized Periopaper strips provided with known test volumes (0.1 microl, 0.2 microl, 0.5 microl and 0.6 microl) were transferred to Periotron 8000 with different time intervals (immediately, 5 s, 30 s and 60 s). For fluid retention, after quantifying the actual volume of the strips provided with known volumes (0.1 microl and 0.6 microl) of two test fluids, a second set of measurements was performed using dry strips. To determine the impact of local conditions (temperature and humidity) and the validity of 3, 5 and 20 replications (0.0-0.6 microl with 0.1- microl increments) on device calibration for 20 degrees C and 25 degrees C, electronic readings were obtained from three devices at three different locations. Differences in volumetric data in each experimental design were statistically analysed.
RESULTS: No significant fluid loss was observed within 5 s, but evaporation clearly led to volumetric distortions with extending transfer times (30 s or 60 s) (p < 0.05). Measurable amounts of fluid retention were found for both volumes and both test fluids, but not with identical patterns. Local conditions resulted in unique calibration data for each test volume and for each device. Although a 5 degrees C increase generally provided higher readings, this was not observed for all devices at all volumes. Additional replicates (n = 5 or n = 20) did not seem to add any further reliability to the triplicate scores for the given test volumes.
CONCLUSION: The findings of the present study confirm the reliability of triplicate readings, and uniqueness of each device and electronic data and the distinct impact of local environmental conditions on the generation/maintenance of calibration scores for each particular device. Furthermore, they underline time-dependent evaporation and fluid retention as additional technical concerns and once again highlight the importance of methodological standardization of the electronic volume quantification process.

Entities:  

Mesh:

Year:  2004        PMID: 15324356     DOI: 10.1111/j.1600-0765.2004.00758.x

Source DB:  PubMed          Journal:  J Periodontal Res        ISSN: 0022-3484            Impact factor:   4.419


  9 in total

1.  Temporomandibular joint function, periodontal health, and oral microbiome in early rheumatoid arthritis and at-risk individuals: a prospective cohort study protocol.

Authors:  J M Kroese; C M C Volgenant; D van Schaardenburg; B G Loos; W Crielaard; F Lobbezoo
Journal:  BDJ Open       Date:  2020-05-19

Review 2.  Wound samples: moving towards a standardised method of collection and analysis.

Authors:  Sarah Ramsay; Linda Cowan; Jeffrey M Davidson; Lillian Nanney; Gregory Schultz
Journal:  Int Wound J       Date:  2015-01-11       Impact factor: 3.315

3.  Biomarker levels in gingival crevicular fluid of generalized aggressive periodontitis patients after non-surgical periodontal treatment.

Authors:  Federica Romano; Loretta Bongiovanni; Laura Bianco; Federica Di Scipio; Zhiqian Yang; Andrea Elio Sprio; Giovanni Nicolao Berta; Mario Aimetti
Journal:  Clin Oral Investig       Date:  2017-09-16       Impact factor: 3.573

4.  Effect of a structured plaque control on MMP-1 and MMP-9 crevicular levels in patients with desquamative gingivitis associated with oral lichen planus.

Authors:  Federica Romano; Paolo G Arduino; Marina Maggiora; Elena Curmei; Valeria Manavella; Roberto Broccoletti; Mario Aimetti
Journal:  Clin Oral Investig       Date:  2018-10-16       Impact factor: 3.573

5.  Early wound healing following one-stage dental implant placement with and without antibiotic prophylaxis: a pilot study.

Authors:  Samer B Khoury; Leslie Thomas; John D Walters; John F Sheridan; Binnaz Leblebicioglu
Journal:  J Periodontol       Date:  2008-10       Impact factor: 6.993

6.  Biochemical markers of bone metabolism in gingival crevicular fluid during early orthodontic tooth movement.

Authors:  German Barbieri; Patricia Solano; Jose Antonio Alarcón; Rolando Vernal; Judith Rios-Lugo; Mariano Sanz; Conchita Martín
Journal:  Angle Orthod       Date:  2012-06-18       Impact factor: 2.079

7.  Comparative volumetric and clinical evaluation of peri-implant sulcular fluid and gingival crevicular fluid.

Authors:  Smiti Bhardwaj; Munivenkatappa Lakshmaiah Venkatesh Prabhuji
Journal:  J Periodontal Implant Sci       Date:  2013-10-29       Impact factor: 2.614

8.  Nitrite and nitrate levels of gingival crevicular fluid and saliva in subjects with gingivitis and chronic periodontitis.

Authors:  Orkun Topcu Ali; Ferda Alev Akalin; Kemal Burak Sahbazoglu; Nermin Yamalik; Kamer Kilinc; Erdem Karabulut; Tolga Fikret Tözüm
Journal:  J Oral Maxillofac Res       Date:  2014-07-01

9.  Temporomandibular joint function, periodontal health, and oral microbiome in early rheumatoid arthritis and at-risk individuals: a prospective cohort study protocol.

Authors:  J M Kroese; C M C Volgenant; D van Schaardenburg; B G Loos; W Crielaard; F Lobbezoo
Journal:  BDJ Open       Date:  2020-05-19
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.