Literature DB >> 15322788

Trace element determination in seawater by ICP-SFMS coupled with a microflow nebulization/desolvation system.

Clara Turetta1, Giulio Cozzi, Carlo Barbante, Gabriele Capodaglio, Paolo Cescon.   

Abstract

Direct and simultaneous determination of Al, Ag, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Pb, Sb, U, V and Zn in diluted (1:10 v:v) seawater from the Antarctic Ocean and the Venice Lagoon at the ng mL(-1) and pg mL(-1) level has been performed by using an inductively coupled plasma sector field mass spectrometer (ICP-SFMS). Samples were analysed by using a PFA microflow nebulizer coupled with a desolvation system or a PFA microflow nebulizer coupled with a Teflon spray chamber, respectively. Measurements were carried out at low (LR, m/Delta m=300), medium (MR, m/Delta m=3,000) and high (HR, m/Delta m=7,500) resolutions depending on the studied isotope. To avoid contamination, sample pre-treatment was carried out in a clean laboratory equipped with a Class 100 vertical laminar flow hood. Concentration ranges (minimum-maximum in ng mL(-1)) found in the Antarctic seawater samples (in depth profiles) were: Ag 0.0004-0.0018, As 0.69-1.32, Cd 0.031-0.096, Co 0.018-0.065, Cr 0.18-0.46, Cu 0.04-1.58, Fe 0.13-1.63, Mn 0.02-0.12, Mo 5.97-12.46, Pb 0.007-0.074, Sb 0.033-0.088, U 0.5-1.9, V 0.6-2.5 and Zn 0.16-0.80. Concentration ranges (min-max in ng mL(-1)) found in the Venice Lagoon water samples (temporal profile from a benthic chamber experiment) were: Al 0.24-0.61, Ag 0.007-0.031, As 1.42-2.27, Cd 0.050-0.182, Co 0.440-1.461, Cr 0.15-0.34, Cu 0.81-2.46, Fe 0.25-1.66, Mn 11.6-31.7, Mo 6.50-10.6, Pb 0.047-0.225, Sb 0.240-0.492, U 1.7-3.3, V 1.3-2.8 and Zn 5.20-21.5. The detection limits range between 0.06 pg mL(-1) for Ag and U to 15 pg mL(-1) for Fe. In order to check the accuracy of the analytical procedure, measurements of the trace elements in a certified reference material (coastal Atlantic seawater, CASS-4-NRCC) were compared with the certified values. In addition, the results from the Antarctic and Venice Lagoon samples were compared with those obtained by using different analytical techniques.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15322788     DOI: 10.1007/s00216-004-2676-0

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  1 in total

1.  How to Efficiently Produce Ultrapure Acids.

Authors:  Damiano Monticelli; Alessio Castelletti; Davide Civati; Sandro Recchia; Carlo Dossi
Journal:  Int J Anal Chem       Date:  2019-01-01       Impact factor: 1.885

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.