Literature DB >> 1532146

Value of a radionuclide limb blood flow technique in the assessment of percutaneous balloon and dynamic angioplasty.

A A Gehani1, P Thorley, K Sheard, S Ashley, S G Brook, M R Rees.   

Abstract

In a prospective study, a radionuclide technique was used to evaluate the limb blood flow (LBF) changes in 30 patients undergoing dynamic (n = 15) or balloon (n = 15) angioplasty for arterial occlusions or stenoses, respectively. The results were compared with Doppler Ankle Brachial Index (DABI) and treadmill exercise tests. Whilst LBF values (ml of blood flow per 100 ml of limb volume per min) were significantly lower in limbs with arterial occlusion than stenosis (4.5 +/- 0.46 and 6.4 +/- 0.74, respectively; P less than 0.05). DABI provided no discrimination. Immediately after balloon angioplasty, there was a fall in DABI, from 0.60 +/- 0.05 to 0.47 +/- 0.04 (P less than 0.05), which rose 24 h later to 0.73 +/- 0.02 (P less than 0.01). Following dynamic angioplasty, DABI improved from 0.60 +/- 0.05 to 0.66 +/- 0.02 (P less than 0.05). At 3 weeks, the LBF improved from 4.6 +/- 0.66 to 11.1 +/- 0.53 (P less than 0.001) following dynamic angioplasty and from 6.2 +/- 0.68 to 8.53 +/- 0.81 (P less than 0.001) following balloon angioplasty. "Normal" LBF (greater than 10 ml/100 ml per min) was achieved in 80% of patients who underwent successful dynamic angioplasty but in only 36% of the balloon group (P less than 0.05, chi 2-test). Reproducibility of repeated LBF measurements in control limbs was superior to that of DABI. This was indicated by a lower coefficient of variation, 13.8% compared with 25.2%, and a higher correlation coefficient, r = 0.79 compared with 0.27. Treadmill exercise tests were invalid or impossible in 30% of all occasions.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1992        PMID: 1532146     DOI: 10.1007/bf00178301

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  18 in total

1.  Percutaneous transluminal angioplasty. A suggested method for analysis of clinical, arteriographic, and hemodynamic factors affecting the results of treatment.

Authors:  R Walden; Y Siegel; Z J Rubinstein; B Morag; A Bass; R Adar
Journal:  J Vasc Surg       Date:  1986-04       Impact factor: 4.268

2.  The measurement of limb blood flow using technetium-labelled red blood cells.

Authors:  A Parkin; P J Robinson; P A Wiggins; S H Leveson; M C Salter; I F Matthews; F M Ware
Journal:  Br J Radiol       Date:  1986-05       Impact factor: 3.039

3.  Intermittent claudication. A comparison between subjective and measured claudication walking distance.

Authors:  J Siggaard-Andersen; F B Petersen
Journal:  Angiology       Date:  1968 Jul-Aug       Impact factor: 3.619

4.  A reliable and readily available method of measuring limb blood flow in intermittent claudication.

Authors:  D Wilkinson; P Vowden; A Parkin; P A Wiggins; P J Robinson; R C Kester
Journal:  Br J Surg       Date:  1987-06       Impact factor: 6.939

5.  Assessment of coronary angioplasty by an automated digital angiographic method.

Authors:  D Katritsis; D A Lythall; M H Anderson; I C Cooper; M W Webb-Peploe
Journal:  Am Heart J       Date:  1988-11       Impact factor: 4.749

6.  Intense microvascular constriction after angioplasty of acute thrombotic coronary arterial lesions.

Authors:  R F Wilson; D D Laxson; J R Lesser; C W White
Journal:  Lancet       Date:  1989-04-15       Impact factor: 79.321

7.  Diagnostic work-up of patients with intermittent claudication.

Authors:  D L Clement
Journal:  Acta Cardiol       Date:  1979       Impact factor: 1.718

8.  Reproducibility of treadmill exercise in patients with intermittent claudication.

Authors:  B Berglund; B Eklund
Journal:  Clin Physiol       Date:  1981-06

9.  Effect of angioplasty-induced endothelial denudation compared with medial injury on regional coronary blood flow.

Authors:  E R Bates; M J McGillem; T F Beals; S F DeBoe; J K Mikelson; G B Mancini; R A Vogel
Journal:  Circulation       Date:  1987-09       Impact factor: 29.690

10.  Variability of Doppler ankle pressures with arterial occlusive disease: an evaluation of ankle index and brachial-ankle pressure gradient.

Authors:  J D Baker; D E Dix
Journal:  Surgery       Date:  1981-01       Impact factor: 3.982

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.