Literature DB >> 15320683

Variation in heart rate during submaximal exercise: implications for monitoring training.

Robert P Lamberts1, Koen A P M Lemmink, Justin J Durandt, Michael I Lambert.   

Abstract

A change in heart rate at a controlled submaximal exercise intensity is used as a marker of training status. However, the standard error of measurement has not been studied systematically, and therefore a change in heart rate, which can be considered relevant, has not been determined. Forty-four subjects (26.5 +/- 5.4 years; mean +/- standard deviation) participated in a submaximal running test at the same time of day for 5 consecutive days. Heart rates were determined during each of the 4 exercise intensities (2 minutes each) of increasing intensity and during the 1-minute recovery period after each stage. The repeatability of the heart rate on a day-to-day basis during the stages and recovery periods were high (intraclass correlation coefficient: 95% confidence interval R = 0.94- 0.99). The lowest variation in heart rate occurred in the fourth stage ( approximately 90% maximum heart rate) with heart rate varying 5 +/- 2 b.min(-1) (95% confidence interval for coefficient of variation = 1.1-1.4%). In conclusion, the standard error of measurement of submaximal heart rate is 1.1-1.4%. This magnitude of measurement error needs to be considered when heart rate is used as a marker of training status.

Mesh:

Year:  2004        PMID: 15320683     DOI: 10.1519/1533-4287(2004)18<641:VIHRDS>2.0.CO;2

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  17 in total

1.  Dissociation of heart rate variability and heart rate recovery in well-trained athletes.

Authors:  C Matthew Lee; Albert Mendoza
Journal:  Eur J Appl Physiol       Date:  2011-11-29       Impact factor: 3.078

2.  Changes in heart rate recovery after high-intensity training in well-trained cyclists.

Authors:  Robert P Lamberts; Jeroen Swart; Timothy D Noakes; Michael I Lambert
Journal:  Eur J Appl Physiol       Date:  2008-12-20       Impact factor: 3.078

Review 3.  Autonomic control of heart rate during and after exercise : measurements and implications for monitoring training status.

Authors:  Jill Borresen; Michael I Lambert
Journal:  Sports Med       Date:  2008       Impact factor: 11.136

4.  Impact of the exercise mode on heart rate recovery after maximal exercise.

Authors:  Micha Tobias Maeder; Peter Ammann; Hans Rickli; Hans Peter Brunner-La Rocca
Journal:  Eur J Appl Physiol       Date:  2008-10-25       Impact factor: 3.078

5.  Influence of Ramadan Fasting on Anaerobic Performance and Recovery Following Short time High Intensity Exercise.

Authors:  Umid Karli; Alpay Guvenc; Alper Aslan; Tahir Hazir; Caner Acikada
Journal:  J Sports Sci Med       Date:  2007-12-01       Impact factor: 2.988

6.  Field based reliability and validity of the bioharness™ multivariable monitoring device.

Authors:  James A Johnstone; Paul A Ford; Gerwyn Hughes; Tim Watson; Andrew C S Mitchell; Andrew T Garrett
Journal:  J Sports Sci Med       Date:  2012-12-01       Impact factor: 2.988

7.  Measuring submaximal performance parameters to monitor fatigue and predict cycling performance: a case study of a world-class cyclo-cross cyclist.

Authors:  Robert P Lamberts; Gerard J Rietjens; Hendrik H Tijdink; Timothy D Noakes; Michael I Lambert
Journal:  Eur J Appl Physiol       Date:  2009-11-18       Impact factor: 3.078

8.  Determinants of the variability of heart rate measures during a competitive period in young soccer players.

Authors:  Martin Buchheit; Alberto Mendez-Villanueva; Marc J Quod; Nicholas Poulos; Pitre Bourdon
Journal:  Eur J Appl Physiol       Date:  2010-03-14       Impact factor: 3.078

9.  Heart rate during sleep: implications for monitoring training status.

Authors:  Miriam R Waldeck; Michael I Lambert
Journal:  J Sports Sci Med       Date:  2003-12-01       Impact factor: 2.988

10.  Monitoring changes in physical performance with heart rate measures in young soccer players.

Authors:  M Buchheit; M B Simpson; H Al Haddad; P C Bourdon; A Mendez-Villanueva
Journal:  Eur J Appl Physiol       Date:  2011-06-09       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.