Literature DB >> 15318860

A comprehensive assessment program to improve blood-administering practices using the FOCUS-PDCA model.

Sunita Saxena1, Lois Ramer, Ira A Shulman.   

Abstract

BACKGROUND: The Joint Commission on the Accreditation of Healthcare Organizations requires that hospitals have a planned approach to systematically collect data on processes related to the use, ordering, and administering of blood components. This study describes how a comprehensive blood-administering assessment program and the FOCUS-PDCA approach improved overall blood-administering practices. STUDY DESIGN AND METHODS: Nurses were trained to observe blood issuance, blood administering, and patient monitoring steps, and to audit patient's charts to measure compliance with blood-ordering procedures. The observations were recorded on a standardized scannable form, which allowed automatic entry of recorded data directly into a computer database.
RESULTS: A total of 982 assessments were completed during the 51-month study period. Documentation of informed consent improved from 80 percent to 100 percent. Compliance with a California law that requires patients to receive information on the risks, benefits, and alternatives to transfusion rose from 30 percent to 100 percent. Physicians' compliance in specifying the rate of blood administration improved from 30 percent to 100 percent, and verification of information on the patient's identification band with the patient's self-identification rose from 50 percent to 100 percent. For all other blood-administering steps, compliance remained high throughout the study period. For the past 9 months, 100-percent compliance has been maintained for all transfusion processes, and during this period no mistransfusions or blood administration near-misses have been reported.
CONCLUSION: The blood-administering assessment program described above has improved transfusion practice, reduced the number of near-miss events, and may have prevented mistransfusions.

Entities:  

Mesh:

Year:  2004        PMID: 15318860     DOI: 10.1111/j.1537-2995.2004.03117.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  5 in total

1.  Evaluation of safety in a radiation oncology setting using failure mode and effects analysis.

Authors:  Eric C Ford; Ray Gaudette; Lee Myers; Bruce Vanderver; Lilly Engineer; Richard Zellars; Danny Y Song; John Wong; Theodore L Deweese
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-05-04       Impact factor: 7.038

2.  Incorporating scannable forms into immunization data collection processes: a mixed-methods study.

Authors:  Christine L Heidebrecht; Susan Quach; Jennifer A Pereira; Sherman D Quan; Faron Kolbe; Michael Finkelstein; David L Buckeridge; Jeffrey C Kwong
Journal:  PLoS One       Date:  2012-12-18       Impact factor: 3.240

3.  Reducing errors in the administration of medication with infusion pumps in the intensive care department: A lean approach.

Authors:  Alexander F van der Sluijs; Eline R van Slobbe-Bijlsma; Astrid Goossens; Alexander Pj Vlaar; Dave A Dongelmans
Journal:  SAGE Open Med       Date:  2019-01-02

4.  Prevalence and factors associated with skin-to-skin contact (SSC) practice: findings from a population-based cross-sectional survey in 10 selected districts of Bangladesh.

Authors:  Nazia Binte Ali; Sabrina Sharmin Priyanka; Bal Ram Bhui; Samantha Herrera; Md Rashidul Azad; Afsana Karim; Zubair Shams; Mahmoodur Rahman; S M Rokonuzzaman; Umme Salma Jahan Meena; Shams El Arifeen; Sk Masum Billah
Journal:  BMC Pregnancy Childbirth       Date:  2021-10-22       Impact factor: 3.007

5.  FOCUS-PDCA can effectively optimize the critical value of test items: FOCUS-PDCA može efikasno da optimizuje kritičnu vrednost ispitivanja.

Authors:  Chunbao Xie; Jianbo Zhang; Jiangrong Luo; Meiling Jian; Taiqiang Zhao; Jiaqiang Wang; Linxi Jiang; Chao Dai; Yao Wei; Li Jiang; Yi Shi
Journal:  J Med Biochem       Date:  2022-07-29       Impact factor: 2.157

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.