Literature DB >> 15318481

Evaluation of electrochemically generated ozone for the disinfection of water and wastewater.

B D Tanner1, S Kuwahara, C P Gerba, K A Reynolds.   

Abstract

Effective wastewater treatment is critical to public health and well-being. This is especially true in developing countries, where disinfection of wastewater is frequently inadequate. People who live in these areas may benefit from wastewater disinfection using ozone. This study evaluated the ability of a new electrochemical process of ozone generation, which produced ozone continuously at high pressure and concentration by the electrolysis of water, to disinfect tap water and secondarily treated wastewater. Inactivation of Klebsiella terrigena, Escherichia coli, MS2 bacteriophage and poliovirus 1 was evaluated first in reverse osmosis (RO) treated water. Inactivation of K. terrigena (6-log), E. coli (6-log), MS2 (6-log) and poliovirus 1 (>3-log) was observed after 1 min of ozonation in a 1 L batch reactor. Experiments were then performed to assess the microbiological impact of disinfection using ozone on secondarily treated municipal wastewater. The effect of ozonation on wastewater was determined for total and faecal coliforms, bacteriophages and heterotrophic plate count (HPC) bacteria. Electrochemical ozone generators provided an effective, rapid and low-cost method of wastewater disinfection. Based on the results of this research, electrochemically generated ozone would be well suited to remote, small-scale, disinfection operations and may provide a feasible means of wastewater disinfection in developing countries.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15318481

Source DB:  PubMed          Journal:  Water Sci Technol        ISSN: 0273-1223            Impact factor:   1.915


  3 in total

1.  Electrode effects on temporal changes in electrolyte pH and redox potential for water treatment.

Authors:  Ali Ciblak; Xuhui Mao; Ingrid Padilla; Dorothy Vesper; Iyad Alshawabkeh; Akram N Alshawabkeh
Journal:  J Environ Sci Health A Tox Hazard Subst Environ Eng       Date:  2012       Impact factor: 2.269

2.  Real-time fluorogenic reverse transcription-PCR assays for detection of bacteriophage MS2.

Authors:  Kevin P O'Connell; Jennifer R Bucher; Patricia E Anderson; Cheng J Cao; Akbar S Khan; Mark V Gostomski; James J Valdes
Journal:  Appl Environ Microbiol       Date:  2006-01       Impact factor: 4.792

3.  Drivers of Microbial Risk for Direct Potable Reuse and de Facto Reuse Treatment Schemes: The Impacts of Source Water Quality and Blending.

Authors:  Rabia M Chaudhry; Kerry A Hamilton; Charles N Haas; Kara L Nelson
Journal:  Int J Environ Res Public Health       Date:  2017-06-13       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.