| Literature DB >> 15313372 |
Donald A Severyn1, Satish C Muluk, David A Vorp.
Abstract
This study addresses the hypothesis that exposure to peripheral arterial (ART) or coronary (COR) hemodynamics and wall biomechanics affect platelet deposition on vein segments. Intact human saphenous vein (HSV) and porcine internal jugular vein (PIJV) segments were studied under venous (VEN), ART, and COR environments using in vitro perfusion systems. Wall shear stress (tau) and circumferential wall stress (sigma(theta)) were calculated for PIJV segments. Platelet deposition was measured using a radioactive assay. PIJV ART segments exhibited a 14% increase in inner diameter over time (P < 0.05). tau, acting on PIJV ART specimens, was less at 6 h compared with time 0 (P < 0.05). sigma(theta) was lower in the VEN specimens compared with ART and COR groups (P < 0.01). Platelet deposition decreased by 40% on PIJV ART segments (P < 0.05) but increased 3.2-fold on PIJV COR segments (P < 0.05) versus VEN control segments. Platelet deposition was increased 1.75-fold in COR HSV cases versus VEN segments. These data indicate that short-term exposure to COR conditions lead to enhanced platelet deposition, whereas ART conditions decrease platelet deposition.Entities:
Mesh:
Substances:
Year: 2004 PMID: 15313372 DOI: 10.1016/j.jss.2004.04.017
Source DB: PubMed Journal: J Surg Res ISSN: 0022-4804 Impact factor: 2.192