Literature DB >> 1531234

Effect of suture material on postoperative astigmatism.

H V Gimbel1, M G Raanan, M DeLuca.   

Abstract

Two hundred patients were enrolled in a randomized, prospective clinical trial comparing the use of 10-0 nylon, 10-0 polypropylene (Prolene), 11-0 polyester (Mersilene), and 10-0 polyethylene (Novafil) suture materials on the amount and decay curves of surgically induced astigmatism following intraocular lens (IOL) surgery. Patients with Mersilene and nylon sutures had the highest amounts of induced with-the-rule (WTR) cylinder (significantly more than Prolene) at one day after surgery. However, the WTR cylinder decayed rapidly for nylon during the first three months but more slowly for Mersilene because of its lack of stretchability. The Prolene group had the lowest level of induced WTR cylinder at one day, but against-the-rule (ATR) drift occurred, leaving cases with ATR astigmatism by a year. The nylon group had the second highest amount of induced WTR cylinder at one day, which had decayed to ATR cylinder by five months. Between one and two years postoperatively, the nylon group experienced a significant ATR shift. The amount of early induced WTR cylinder seemed to be related to the knot-tying technique and tissue gripping characteristics, whereas the shape of the decay curve was related to the material characteristics of the suture.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1531234     DOI: 10.1016/s0886-3350(13)80382-3

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  4 in total

1.  Surgically induced astigmatism in combined phacoemulsification and vitrectomy; 23-gauge transconjunctival sutureless vitrectomy versus 20-gauge standard vitrectomy.

Authors:  Dong Ho Park; Jae Pil Shin; Si Yeol Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-05-14       Impact factor: 3.117

2.  Effect of disagreement between refractive, keratometric, and topographic determination of astigmatic axis on suture removal after penetrating keratoplasty.

Authors:  A R Sarhan; H S Dua; M Beach
Journal:  Br J Ophthalmol       Date:  2000-08       Impact factor: 4.638

3.  Thae use of microfluic spinning fiber as an ophthalmology suture showing the good anastomotic strength control.

Authors:  DoYeun Park; In Sung Yong; Kyong Jin Cho; Jie Cheng; Youngmee Jung; Soo Hyun Kim; Sang-Hoon Lee
Journal:  Sci Rep       Date:  2017-11-24       Impact factor: 4.379

4.  Silane Coupling Agent Modifies the Mechanical Properties of a Chitosan Microfiber.

Authors:  Yuki Shirosaki; Toshinobu Okabayashi; Saki Yasutomi
Journal:  Molecules       Date:  2020-11-13       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.