Thermal elevation in the human eye and head due to the operation of a retinal prosthesis.

Keyoor Gosalia1, James Weiland, Mark Humayun, Gianluca Lazzi.   

Abstract

An explicit finite-difference time-domain formulation of the bio-heat equation is employed with a three-dimensional head eye model to evaluate the temperature increase in the eye and surrounding head tissues due to the operation of the implanted stimulator IC chip of a retinal prosthesis designed to restore partial vision to the blind. As a first step, a validation of the thermal model and method used is carried out by comparison with in vivo measurements of intraocular heating performed in the eyes of dogs. Induced temperature increase in the eye and surrounding tissues is then estimated for several different operational conditions of the implanted chip. In the vitreous cavity, temperature elevation of 0.26 degrees C is observed after 26 min for a chip dissipating 12.4 mW when positioned in the mid-vitreous cavity while it is 0.16 degrees C when the chip is positioned in the anterior portion between the eye's ciliary muscles. Corresponding temperature rises observed on chip are 0.82 degrees C for both the positions of the chip. A comprehensive account of temperature elevations in different tissues under different operational conditions is presented.

Entities:  

Mesh:

Year:  2004        PMID: 15311834     DOI: 10.1109/TBME.2004.827548

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  6 in total

1.  3D computational study of non-invasive patient-specific microwave hyperthermia treatment of breast cancer.

Authors:  Earl Zastrow; Susan C Hagness; Barry D Van Veen
Journal:  Phys Med Biol       Date:  2010-06-04       Impact factor: 3.609

2.  Feasibility of Neural Stimulation With Floating-Light-Activated Microelectrical Stimulators.

Authors:  Ammar Abdo; Mesut Sahin
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2011-04-05       Impact factor: 3.833

3.  THERMAL ANALYSIS OF INTRAOCULAR ELECTRONIC DISPLAY PROJECTOR VISUAL PROSTHESIS.

Authors:  D Gongal; S Thakur; A Panse; R Pawar; C Q Yu; C D Foster
Journal:  Numeri Heat Transf A Appl       Date:  2020-08-14       Impact factor: 2.928

Review 4.  Review of Thermal and Physiological Properties of Human Breast Tissue.

Authors:  Jeantide Said Camilleri; Lourdes Farrugia; Sergio Curto; Dario B Rodrigues; Laura Farina; Gordon Caruana Dingli; Julian Bonello; Iman Farhat; Charles V Sammut
Journal:  Sensors (Basel)       Date:  2022-05-20       Impact factor: 3.847

Review 5.  Visual prostheses: the enabling technology to give sight to the blind.

Authors:  Mohammad Hossein Maghami; Amir Masoud Sodagar; Alireza Lashay; Hamid Riazi-Esfahani; Mohammad Riazi-Esfahani
Journal:  J Ophthalmic Vis Res       Date:  2014 Oct-Dec

Review 6.  Wireless Wearables and Implants: A Dosimetry Review.

Authors:  Katrina Guido; Asimina Kiourti
Journal:  Bioelectromagnetics       Date:  2019-12-18       Impact factor: 1.848

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.