Literature DB >> 1530824

Prevention of graft infection by bonding of gentamycin to Dacron prostheses.

A Haverich1, S Hirt, M Karck, F Siclari, H Wahlig.   

Abstract

To increase the efficacy of perioperative antibiotic prophylaxis in vascular surgery an experimental study including topical application of the gentamicin derivative EMD 46/217 and fibrin sealant as antibiotic carrier to Dacron prostheses was initiated. In vitro treatment of Dacron with gentamicin and fibrin was followed by constant antibiotic release for 3 weeks. In a subsequent animal study Dacron grafts were implanted in the aorta of 10 pigs after direct contamination with Staphylococcus aureus solution. One graft was pretreated with the antibiotic/fibrin compound, a second with the antibiotic alone. Grafts 3 (no pretreatment) and 4 (fibrin alone) served as controls. After 1 week the grafts and their corresponding implantation sites were excised for measurement of antibiotic content and for culture. The antibiotic content of grafts with the antibiotic/fibrin compound was 25.0 +/- 7.2 micrograms/gm wet weight, whereas Dacron pretreated with the antibiotic alone contained no measurable drug amounts except for one specimen (0.5 microgram/gm) (antibiotic/fibrin vs antibiotic, p less than .0005). The corresponding implantation sites to antibiotic/fibrin grafts contained 1.07 +/- 0.54 microgram/gm antibiotic, whereas in only 2/10 implantation sites of antibiotic grafts low antibiotic levels were found (0.05 and 0.2 microgram/gm) (antibiotic/fibrin vs antibiotic, p less than 0.005). All control grafts and 9/10 antibiotic grafts were infected. By contrast, only five were contaminated, and 5 of 10 remained sterile after culture (antibiotic/fibrin vs antibiotic, p less than 0.05). This finding correlates with the antibiotic content in the Dacron. It is concluded that pretreatment of prosthetic Dacron grafts with the antibiotic/fibrin compound results in binding of sufficient amounts of antibiotic for at least 1 week.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1530824     DOI: 10.1067/mva.1992.30301

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  4 in total

1.  The fate of homograft tracheal transplants in sheep.

Authors:  Matthias Behrend; Eva Kluge
Journal:  World J Surg       Date:  2008-08       Impact factor: 3.352

2.  Angiogenesis in a patient with ischemic limb induced by intramuscular injection of vascular endothelial growth factor and fibrin platform.

Authors:  N Kipshidze; V Chekanov; P Chawla; L R Shankar; J B Gosset; K Kumar; D Hammen; J Gordon; M H Keelan
Journal:  Tex Heart Inst J       Date:  2000

3.  New anti-infective coatings of medical implants.

Authors:  F D Matl; A Obermeier; S Repmann; W Friess; A Stemberger; K-D Kuehn
Journal:  Antimicrob Agents Chemother       Date:  2008-03-24       Impact factor: 5.191

Review 4.  ECM-based materials in cardiovascular applications: Inherent healing potential and augmentation of native regenerative processes.

Authors:  Anna V Piterina; Aidan J Cloonan; Claire L Meaney; Laura M Davis; Anthony Callanan; Michael T Walsh; Tim M McGloughlin
Journal:  Int J Mol Sci       Date:  2009-11-20       Impact factor: 6.208

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.