Literature DB >> 15308230

Electrochemical modulation of antigen-antibody binding.

J Justin Gooding1, Christine Wasiowych, Donald Barnett, D Brynn Hibbert, Joseph N Barisci, Gordon G Wallace.   

Abstract

The label-free amperometric detection of a rabbit IgG antigen by an anti-rabbit IgG antibody is achieved by observing the electrochemistry at a glassy carbon electrode modified with antibody entrapped in an electrodeposited polypyrrole membrane. In a flow injection apparatus the electrode is pulsed between -0.2 and +0.4 V versus Ag/AgCl. The pulsing of the electrode switches the polypyrrole membrane between the oxidised and reduced states. When antigen is injected into the flow stream a change in current is observed at the electrode despite the antigen or antibody being redox inactive at the potentials employed. It is proposed that this current is due to a change in the flux of ions into and out of the polypyrrole matrix during a pulse when the poly-anionic antigen is present. The immunoreaction was reversible because the 200 ms pulse at each potential was too short to allow secondary bonding forces (hydrogen bonding and hydrophobic forces) which are responsible for the strength of the antibody-antigen complex to be established. The consequence of the reversibility of the antigen-antibody binding is a low apparent affinity constant but an easily regenerated recognition interface.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15308230     DOI: 10.1016/j.bios.2004.01.010

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Label-Free Impedance Biosensors: Opportunities and Challenges.

Authors:  Jonathan S Daniels; Nader Pourmand
Journal:  Electroanalysis       Date:  2007-05-16       Impact factor: 3.223

Review 2.  Electrochemical Sensors Based on Organic Conjugated Polymers.

Authors:  Md Aminur Rahman; Pankaj Kumar; Deog-Su Park; Yoon-Bo Shim
Journal:  Sensors (Basel)       Date:  2008-01-09       Impact factor: 3.576

3.  Antigen detection via the rate of ion current rectification change of the antibody-modified glass nanopore membrane.

Authors:  Anna E P Schibel; Eric N Ervin
Journal:  Langmuir       Date:  2014-09-09       Impact factor: 3.882

4.  Graphene quantum dot modified glassy carbon electrode for the determination of doxorubicin hydrochloride in human plasma.

Authors:  Nastaran Hashemzadeh; Mohammad Hasanzadeh; Nasrin Shadjou; Jamal Eivazi-Ziaei; Maryam Khoubnasabjafari; Abolghasem Jouyban
Journal:  J Pharm Anal       Date:  2016-03-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.