Literature DB >> 15304044

Standardization of factor VIII and von Willebrand factor in plasma: calibration of the WHO 5th International Standard (02/150).

A R Hubbard1, A B Heath.   

Abstract

Calibration of the 5th International Standard factor (F)VIII/von Willebrand factor in plasma (02/150) (5th IS) for five parameters [factor VIII: coagulant activity (FVIII:C); FVIII: antigen (FVIII:Ag), von Willebrand factor: antigen (VWF:Ag), von Willebrand factor: ristocetin cofactor (VWF:RCo), von Willebrand factor: collagen binding (VWF:CB)] was achieved through an international collaborative study involving 37 laboratories. Estimates calculated relative to the previous 4th IS and locally prepared normal plasma pools were not significantly different for estimates of FVIII:Ag, VWF:Ag, VWF:RCo and VWF:CB and hence mean values calculated relative to the 4th IS of 0.94, 0.91, 0.78 and 0.94 IU ampoule(-1), respectively, were assigned. However, estimates for FVIII:C relative to the fresh normal pools (mean 0.61 IU ampoule(-1)) were significantly lower than estimates relative to the 4th IS (mean 0.68 IU ampoule(-1)). In consideration of the good stability of FVIII:C in the 4th IS and the variability of estimates relative to the local pools it was agreed to assign the mean value obtained relative to the 4th IS of 0.68 IU ampoule(-1). For all five parameters the interlaboratory variability (geometric coefficient of variation, GCV%) was larger for estimates calculated relative to the normal pools (range 12.6-16.5%) when compared with estimates calculated relative to the 4th IS (range 3.5-8.3%). An accelerated degradation study performed in six laboratories indicated that the five calibrated parameters are extremely stable when ampoules are stored at -20 degrees C. Mean estimates of predicted loss per year at -20 degrees C ranged from 0% for VWF:CB to 0.029% for VWF:RCo. The 5th IS (02/150) was established by the World Health Organization in November 2003.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15304044     DOI: 10.1111/j.1538-7836.2004.00838.x

Source DB:  PubMed          Journal:  J Thromb Haemost        ISSN: 1538-7836            Impact factor:   5.824


  5 in total

1.  Correction of a murine model of von Willebrand disease by gene transfer.

Authors:  Robert G Pergolizzi; Guangchun Jin; Diane Chan; Lorraine Pierre; James Bussel; Barbara Ferris; Philip L Leopold; Ronald G Crystal
Journal:  Blood       Date:  2006-04-25       Impact factor: 22.113

Review 2.  Laboratory testing for von Willebrand disease: toward a mechanism-based classification.

Authors:  Richard Torres; Yuri Fedoriw
Journal:  Clin Lab Med       Date:  2009-06       Impact factor: 1.935

3.  Biological markers of lung injury before and after the institution of positive pressure ventilation in patients with acute lung injury.

Authors:  Magda Cepkova; Sandra Brady; Anil Sapru; Michael A Matthay; Gwynne Church
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

4.  The VITRO Score (Von Willebrand Factor Antigen/Thrombocyte Ratio) as a New Marker for Clinically Significant Portal Hypertension in Comparison to Other Non-Invasive Parameters of Fibrosis Including ELF Test.

Authors:  Stephanie Hametner; Arnulf Ferlitsch; Monika Ferlitsch; Alexandra Etschmaier; Rainer Schöfl; Alexander Ziachehabi; Andreas Maieron
Journal:  PLoS One       Date:  2016-02-19       Impact factor: 3.240

Review 5.  Innovative approach for improved rFVIII concentrate.

Authors:  Massimo Morfini
Journal:  Eur J Haematol       Date:  2014-05-22       Impact factor: 2.997

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.