Literature DB >> 15296641

Miniaturization of intracellular calcium functional assays to 1536-well plate format using a fluorometric imaging plate reader.

Peter Hodder1, Rebecca Mull, Jason Cassaday, Kurtis Berry, Berta Strulovici.   

Abstract

The measurement of intracellular calcium response transients in living mammalian cells is a popular functional assay for identification of agonists and antagonists to receptors or channels of pharmacological interest. In recent years, advances in fluorescence-based detection techniques and automation technologies have facilitated the adaptation of this assay to 384-well microplate format high-throughput screening (HTS) assays. However, the cost and time required performing the intracellular calcium HTS assays in the 384-well format can be prohibitive for HTS campaigns of greater than 1 x 10(6) wells. For these reasons, it is attractive to miniaturize intracellular calcium functional assays to the 1536-well microplate format, where assay volumes and plate throughput can be decreased by several fold. The focus of the research described in this article is the miniaturization of an intracellular calcium assay to 1536-well plate format. This was accomplished by modifying the hardware and software of a fluorometric imaging plate reader (FLIPR) to enable transfer of nanoliters of test compound directly to a 1536-well assay plate, and measure the resulting calcium response from all 1536 wells simultaneously. An intracellular calcium functional assay against the rat muscarinic acetylcholine receptor subtype 1 (rmAchR1) G-protein coupled receptor (GPCR) was miniaturized and executed on this modified instrument. In experiments measuring the activity of known muscarinic receptor agonists and antagonists, the miniaturized FLIPR assay gave EC(50) and IC(50) values and rank order potency comparable to the 384-well format assays. Calculated Z' factors for the miniaturized agonist and antagonist assays were, respectively, 0.56 +/- 0.21 and 0.53 +/- 0.22, which were slightly higher (Z'(agonist) = 0.55 +/- 0.33) and lower (Z'(antagonist) = 0.70 +/- 0.18) than the corresponding values in the 384-well assays. A mock agonist HTS campaign against the muscarinic receptor in miniaturized format was able to identify all wells spiked with the rmAchR1 agonist carbachol.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15296641     DOI: 10.1177/1087057104264038

Source DB:  PubMed          Journal:  J Biomol Screen        ISSN: 1087-0571


  9 in total

Review 1.  Elusive equilibrium: the challenge of interpreting receptor pharmacology using calcium assays.

Authors:  Steven J Charlton; Georges Vauquelin
Journal:  Br J Pharmacol       Date:  2010-11       Impact factor: 8.739

2.  The highly efficacious actions of N-desmethylclozapine at muscarinic receptors are unique and not a common property of either typical or atypical antipsychotic drugs: is M1 agonism a pre-requisite for mimicking clozapine's actions?

Authors:  Marilyn A Davies; Beth Ann Compton-Toth; Sandra J Hufeisen; Herbert Y Meltzer; Bryan L Roth
Journal:  Psychopharmacology (Berl)       Date:  2004-10-13       Impact factor: 4.530

3.  Enzyme microarrays assembled by acoustic dispensing technology.

Authors:  E Y Wong; S L Diamond
Journal:  Anal Biochem       Date:  2008-06-20       Impact factor: 3.365

4.  Rapid and label-free screening of enzyme inhibitors using segmented flow electrospray ionization mass spectrometry.

Authors:  Jian Pei; Qiang Li; Robert T Kennedy
Journal:  J Am Soc Mass Spectrom       Date:  2010-02-10       Impact factor: 3.109

5.  A multiplex calcium assay for identification of GPCR agonists and antagonists.

Authors:  Ke Liu; Noel Southall; Steve A Titus; James Inglese; Robert L Eskay; Paul Shinn; Christopher P Austin; Markus A Heilig; Wei Zheng
Journal:  Assay Drug Dev Technol       Date:  2010-06       Impact factor: 1.738

6.  Multiplexed random peptide library and phospho-specific antibodies facilitate human polo-like kinase 1 inhibitor screen.

Authors:  Kenji Tanaka; Mitsunori Koresawa; Masato Iida; Kazuhiro Fukasawa; Erica Stec; Jason Cassaday; Peter Chase; Keith Rickert; Peter Hodder; Toshimitsu Takagi; Hideya Komatani
Journal:  Assay Drug Dev Technol       Date:  2010-02       Impact factor: 1.738

7.  Identification of Metabotropic Glutamate Receptor Subtype 5 Potentiators Using Virtual High-Throughput Screening.

Authors:  Ralf Mueller; Alice L Rodriguez; Eric S Dawson; Mariusz Butkiewicz; Thuy T Nguyen; Stephen Oleszkiewicz; Annalen Bleckmann; C David Weaver; Craig W Lindsley; P Jeffrey Conn; Jens Meiler
Journal:  ACS Chem Neurosci       Date:  2010-01-28       Impact factor: 4.418

8.  Novel patient cell-based HTS assay for identification of small molecules for a lysosomal storage disease.

Authors:  Haifeng Geng; Grace Whiteley; Jameson Ribbens; Wei Zheng; Noel Southall; Xin Hu; Juan J Marugan; Marc Ferrer; Gustavo H B Maegawa
Journal:  PLoS One       Date:  2011-12-21       Impact factor: 3.240

9.  Coupling Droplet Microfluidics with Mass Spectrometry for Ultrahigh-Throughput Analysis of Complex Mixtures up to and above 30 Hz.

Authors:  Emily E Kempa; Clive A Smith; Xin Li; Bruno Bellina; Keith Richardson; Steven Pringle; James L Galman; Nicholas J Turner; Perdita E Barran
Journal:  Anal Chem       Date:  2020-08-25       Impact factor: 6.986

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.