Literature DB >> 15295763

The supine hip extensor manual muscle test: a reliability and validity study.

Jacquelin Perry1, Walter B Weiss, Judith M Burnfield, JoAnne K Gronley.   

Abstract

OBJECTIVES: To define the relative hip extensor muscle strengths values identified by the 4 grades obtained with a supine manual muscle test (MMT) and to compare these values with those indicated by the traditional prone test.
DESIGN: Comparison of 4 manual supine strength grades with isometric hip extension joint torque; kappa statistic-determined interrater reliability, and analyses of variance identified between grade differences in torque.
SETTING: Pathokinesiology laboratory. PARTICIPANTS: Adult volunteers recruited from local community and outpatient clinics. Reliability testing: 16 adults with postpolio (31 limbs). Validity testing (2 groups): 18 subjects without pathology (18 limbs), and 26 people with clinical signs of hip extensor weakness (51 limbs).
INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Supine hip extensor manual muscle grade and isometric hip extension torque.
RESULTS: Reliability testing showed excellent agreement (82%). Subjects with pathology had significant differences in mean torque (P<.01) for the assigned grade 5 (176 Nm), grade 4 (103 Nm), grade 3 (67 Nm), and grade 2 (19 Nm). Healthy adults showed significant differences between grade 5 (212 Nm) and grade 4 (120 Nm) in mean torque (P<.05).
CONCLUSIONS: The supine MMT is a reliable and valid method with which to assess hip extension strength.

Entities:  

Mesh:

Year:  2004        PMID: 15295763     DOI: 10.1016/j.apmr.2003.09.019

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  9 in total

1.  Shoulder manual muscle resistance test cannot fully detect muscle weakness.

Authors:  Takayuki Nagatomi; Tatsuo Mae; Teruyoshi Nagafuchi; Shin-Ichi Yamada; Koutatsu Nagai; Minoru Yoneda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-11-21       Impact factor: 4.342

2.  Inter-rater reliability of manual muscle strength testing in ICU survivors and simulated patients.

Authors:  Eddy Fan; Nancy D Ciesla; Alex D Truong; Vinodh Bhoopathi; Scott L Zeger; Dale M Needham
Journal:  Intensive Care Med       Date:  2010-03-06       Impact factor: 17.440

3.  Validity of the Handheld Dynamometer Compared with an Isokinetic Dynamometer in Measuring Peak Hip Extension Strength.

Authors:  Heather Keep; Levana Luu; Ayli Berson; S Jayne Garland
Journal:  Physiother Can       Date:  2016       Impact factor: 1.037

4.  Physical therapy management of complex regional pain syndrome I in a 14-year-old patient using strain counterstrain: a case report.

Authors:  Cristiana Kahl Collins
Journal:  J Man Manip Ther       Date:  2007

5.  Manual muscle strength testing of critically ill patients: feasibility and interobserver agreement.

Authors:  Catherine L Hough; Binh K Lieu; Ellen S Caldwell
Journal:  Crit Care       Date:  2011-01-28       Impact factor: 9.097

Review 6.  Canine Geriatric Rehabilitation: Considerations and Strategies for Assessment, Functional Scoring, and Follow Up.

Authors:  Christopher Frye; Brittany Jean Carr; Margret Lenfest; Allison Miller
Journal:  Front Vet Sci       Date:  2022-02-25

7.  Reliability of a new stabilized dynamometer system for the evaluation of hip strength.

Authors:  Timothy W Tourville; Helen C Smith; Sandra J Shultz; Pamela M Vacek; James R Slauterbeck; Robert J Johnson; Bruce D Beynnon
Journal:  Sports Health       Date:  2013-03       Impact factor: 3.843

8.  On the reliability and validity of manual muscle testing: a literature review.

Authors:  Scott C Cuthbert; George J Goodheart
Journal:  Chiropr Osteopat       Date:  2007-03-06

9.  The effects of hip muscle strengthening on knee load, pain, and function in people with knee osteoarthritis: a protocol for a randomised, single-blind controlled trial.

Authors:  Kim L Bennell; Michael A Hunt; Tim V Wrigley; David J Hunter; Rana S Hinman
Journal:  BMC Musculoskelet Disord       Date:  2007-12-07       Impact factor: 2.362

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.