Literature DB >> 15295327

Effect of different high-palladium metal-ceramic alloys on the color of opaque and dentin porcelain.

Minos M Stavridakis1, Efstratios Papazoglou, Robert R Seghi, William M Johnston, William A Brantley.   

Abstract

STATEMENT OF PROBLEM: The color of dental porcelain depends on the type of metal substrate. Little research has been done to document the effects of different types of high-palladium alloys on the color of dental porcelain.
PURPOSE: The purpose of this in vitro study was to evaluate the effects of different high-palladium alloys on the resulting color of dentin porcelain, as well as on that of opaque porcelain after simulated dentin and glazing firing cycles.
MATERIAL AND METHODS: Three Pd-Cu-Ga alloys, Spartan Plus (S), Liberty (B), and Freedom Plus (F), and 5 Pd-Ga alloys, Legacy (L), IS 85 (I), Protocol (P), Legacy XT (X), and Jelenko No.1 (N), were examined. A Pd-Ag alloy, Super Star (T), was included for comparison to the high-palladium alloys, and the Au-Pd alloy, Olympia (O), served as the control. Six cast discs (16 x 1 mm) were prepared from each of the alloys. Shade B1 opaque porcelain (Vita-Omega) was applied at a final thickness of 0.1 mm. After 2 opaque porcelain firing cycles, the surfaces were airborne-particle abraded, and the specimens were divided into 2 groups. In the first group, 0.9 mm of B1 dentin porcelain was applied. The other group of specimens with only opaque porcelain underwent the same dentin porcelain and glazing firing cycles. Color differences (DeltaE) were determined with a colorimeter between the control and each experimental group, after the second opaque porcelain, second dentin porcelain, and glazing firing cycles. One-way analysis of variance and Dunnett's multiple range test were performed on the DeltaE data (alpha=.05).
RESULTS: After the application of dentin porcelain, the 3 Pd-Cu-Ga alloys showed significantly different (P<.05) DeltaE values (S=2.3 +/- 0.5, B=1.4 +/- 0.3, and F=1.3 +/- 0.7) than the control group. After the glazing cycle of this group, the 3 Pd-Cu-Ga alloys and the Pd-Ag alloy exhibited significantly different (P<.05) DeltaE values (S=2.8 +/- 0.8, B=2.2 +/- 0.3, F=1.9 +/- 1.0, and T=1.4 +/- 0.5) than the control group. After the simulated dentin porcelain firing cycles, the specimens with only opaque porcelain exhibited significantly different (P<.05) DeltaE values (S=5.2 +/- 1.4, B=5.4 +/- 0.6, and F=3.9 +/- 0.2) than the control group. The color difference between the 3 Pd-Cu-Ga alloys with only opaque porcelain and the control group increased more after the simulated glazing cycle (S=6.6 +/- 1.5, B=6.3 +/- 0.5, and F=4.6 +/- 0.1). The observed color differences between the Pd-Ga alloys and the control group were not statistically significant at any point.
CONCLUSIONS: The Pd-Cu-Ga alloys with only opaque porcelain, after the simulated dentin porcelain and glazing firing cycles, exhibited clinically unacceptable color differences. The application of dentin porcelain to the Pd-Cu-Ga alloys resulted in clinically acceptable color differences. The application of dentin porcelain to the Pd-Ag alloy, after the glazing firing cycle, resulted in clinically acceptable color differences (approximately 2.8 to 3.7 DeltaE CIELAB units). The Pd-Ag alloy specimens with only opaque porcelain did not exhibit significant color differences from the control group, whereas significant color differences from the control group after the dentin porcelain and glazing firing cycles were still clinically acceptable.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15295327     DOI: 10.1016/j.prosdent.2004.05.001

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Study of Pd-Ag dental alloys: examination of effect of casting porosity on fatigue behavior and microstructural analysis.

Authors:  D Li; N Baba; W A Brantley; S B Alapati; R H Heshmati; G S Daehn
Journal:  J Mater Sci Mater Med       Date:  2010-07-10       Impact factor: 3.896

2.  Spectrophotometric comparison of two porcelain systems, VMK master and VM13 with the VITA 3D-master shade guide (An in vitro study).

Authors:  Assadollah Ahmadzadeh; Sara Mansourinejad; Sanaz Mansourinejad; Ali Rohani
Journal:  Dent Res J (Isfahan)       Date:  2022-04-27

3.  Comparison of the Effect of Different Ceramic Alloys and Porcelain Systems upon the Color of Metal-Ceramic Restorations: An In Vitro Study.

Authors:  K V Anitha; M Dhanraj; R Haribabu
Journal:  J Indian Prosthodont Soc       Date:  2013-03-14

4.  The Effect of Laboratory Procedures and Repeated-glazing on Color of Metal-ceramic Restoration.

Authors:  Hatice Özdemir; Zeynep Yesil Duymus
Journal:  Contemp Clin Dent       Date:  2019 Apr-Jun
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.