Literature DB >> 15293886

Diagnostic accuracy of ELISA methods as an alternative screening test to indirect immunofluorescence for the detection of antinuclear antibodies. Evaluation of five commercial kits.

Elio Tonuttia1, Danila Bassetti, Anna Piazza, Daniela Visentini, Monica Poletto, Franca Bassetto, Patrizio Caciagli, Danilo Villalta, Renato Tozzoli, Nicola Bizzaro.   

Abstract

Detection of antinuclear antibodies (ANA) is a fundamental laboratory test for diagnosing systemic autoimmune diseases. Currently, the method of choice is indirect immunofluorescence (IIF) on a HEp-2 cell substrate. The goal of this study was to evaluate the diagnostic accuracy of five commercially available enzyme immunoassay (EIA) kits for ANA detection and to verify the possibility of using them as an alternative to the IIF method. The study involved 1513 patients, 315 of whom were diagnosed with a systemic autoimmune disease and 1198 in whom an autoimmune disorder was excluded. For all sera, ANA detection was performed via IIF and with five different EIA kits. The results were evaluated in relation to clinical diagnosis and the presence of possible specific autoantibodies (anti-ENA or anti-dsDNA); lastly, they were compared with the results obtained using ANA-IIF as the method of reference. The positive rate of the ANA-IIF test in subjects with systemic autoimmune diseases was 92%, whereas in the five ANA-EIA kits there was broad diversity in terms of response, with positive rates ranging from 74 to 94%. All the EIA kits correctly detected the presence of antibodies (anti-dsDNA, anti-RNP, anti-Ro/SSA) responsible for homogeneous and speckled fluorescence pattern, but at the same time they showed substantial inaccuracy with the nucleolar pattern, with a mean sensitivity of approximately 50% in this case. Instead, there was a large kit-to-kit difference in terms of identification of anti-Scl70 and centromere patterns, for which sensitivities ranged between 45 and 91%, and between 49 and 100%, respectively. The results of the study demonstrate that the commercially available ANA-EIA kits show different levels of sensitivity and specificity. Some of them have a diagnostic accuracy that is comparable and, in some cases, even higher than the IIF method. Consequently, these could be used as an alternative screening test to IIE. However, others do not ensure acceptable results. Therefore, careful evaluation of the various kits on the market is advisable before including any of these methods in the clinical and diagnostic testing.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15293886     DOI: 10.1080/08916930310001657010

Source DB:  PubMed          Journal:  Autoimmunity        ISSN: 0891-6934            Impact factor:   2.815


  10 in total

1.  Clinical performance evaluation of a novel, automated chemiluminescent immunoassay, QUANTA Flash CTD Screen Plus.

Authors:  Chelsea Bentow; Gabriella Lakos; Rachel Rosenblum; Cassandra Bryant; Andrea Seaman; Michael Mahler
Journal:  Immunol Res       Date:  2015-02       Impact factor: 2.829

2.  The burden of the variability introduced by the HEp-2 assay kit and the CAD system in ANA indirect immunofluorescence test.

Authors:  M Infantino; F Meacci; V Grossi; M Manfredi; M Benucci; M Merone; P Soda
Journal:  Immunol Res       Date:  2017-02       Impact factor: 2.829

Review 3.  Recent Approaches To Optimize Laboratory Assessment of Antinuclear Antibodies.

Authors:  Anne E Tebo
Journal:  Clin Vaccine Immunol       Date:  2017-12-05

4.  Computer-assisted pattern recognition of autoantibody results.

Authors:  Steven R Binder; Mark C Genovese; Joan T Merrill; Robert I Morris; Allan L Metzger
Journal:  Clin Diagn Lab Immunol       Date:  2005-12

Review 5.  Interstitial Pneumonia With Autoimmune Features: An Emerging Challenge at the Intersection of Rheumatology and Pulmonology.

Authors:  Erin M Wilfong; Robert J Lentz; Adam Guttentag; James J Tolle; Joyce E Johnson; Jonathan A Kropski; Peggy L Kendall; Timothy S Blackwell; Leslie J Crofford
Journal:  Arthritis Rheumatol       Date:  2018-10-27       Impact factor: 10.995

6.  Automation in indirect immunofluorescence testing: a new step in the evolution of the autoimmunology laboratory.

Authors:  Renato Tozzoli; Antonio Antico; Brunetta Porcelli; Danila Bassetti
Journal:  Auto Immun Highlights       Date:  2012-07-13

Review 7.  Toward a new autoantibody diagnostic orthodoxy: understanding the bad, good and indifferent.

Authors:  Marvin J Fritzler
Journal:  Auto Immun Highlights       Date:  2012-03-21

Review 8.  Current concepts and future directions for the assessment of autoantibodies to cellular antigens referred to as anti-nuclear antibodies.

Authors:  Michael Mahler; Pier-Luigi Meroni; Xavier Bossuyt; Marvin J Fritzler
Journal:  J Immunol Res       Date:  2014-04-27       Impact factor: 4.818

Review 9.  Missing links in high quality diagnostics of inflammatory systemic rheumatic diseases: It is all about the patient!

Authors:  Allan S Wiik; Nicola Bizzaro
Journal:  Auto Immun Highlights       Date:  2012-04-11

10.  Interpretation of ANA indirect immunofluorescence test outside the darkroom using NOVA view compared to manual microscopy.

Authors:  Susan S Copple; Troy D Jaskowski; Rashelle Giles; Harry R Hill
Journal:  J Immunol Res       Date:  2014-02-24       Impact factor: 4.818

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.