| Literature DB >> 15293408 |
Abstract
A new method was devised for measuring the pH of a concrete surface by pHBOY-P2 with a piece of filter paper by extracting the pH value from concrete. This is a simple and inexpensive method that does not damage the concrete building, and is easy to apply on concrete samples for monitoring. By using the method mentioned above, a drastic decrease of the pH value of concrete bridges and buildings has investigated. The method is environmentally friendly to detect the pH value change of concrete as an environmental sample investigation.Year: 2004 PMID: 15293408 DOI: 10.2116/analsci.20.1087
Source DB: PubMed Journal: Anal Sci ISSN: 0910-6340 Impact factor: 2.081