Literature DB >> 15292425

Preoperative marking of musculoskeletal tumors guided by magnetic resonance imaging.

Philippe L Pereira1, Jan Fritz, Claudius W Koenig, Franz Maurer, Paul Boehm, Andreas Badke, Markus Mueller-Schimpfle, Michael Bitzer, Claus D Claussen.   

Abstract

BACKGROUND: The purpose of this study was to evaluate a new stereotactic method for preoperative coil-marking of musculoskeletal tumors with use of interventional magnetic resonance imaging.
METHODS: Nine patients with a soft-tissue or bone-marrow tumor were referred to our department for preoperative marking of the extent of the lesion. In one patient, two lesions were marked. Guidance for the punctures and the delivery of the coils was provided by an open low-field magnetic resonance imaging system with horizontal access. After imaging of the extent of the lesion, magnetic resonance imaging-compatible titanium coils were placed with use of nearly real-time or step-by-step magnetic resonance imaging control. The coils were placed up to seventy-two hours before the surgery. The inclusion of the tumor borders within the area of the excision was examined with cross-sectional histological analysis of surgical specimens.
RESULTS: The tumor-marking intervention was successfully performed with the guidance of magnetic resonance imaging only in all patients. Preoperatively, nineteen coils were used to mark the ten lesions in the nine patients. All of the coils were easily located with intraoperative fluoroscopy. No coil migrated between the time of the percutaneous marking and the surgery. Histological examination of the resection borders revealed no residual tumor cells. No complications were observed, and, after a mean of twenty-three months of follow-up, no tumor had recurred.
CONCLUSIONS: Preoperative coil-marking guided by magnetic resonance imaging for exact delineation of a musculoskeletal tumor is technically feasible and can readily demonstrate the full extent of the tumor. Use of magnetic resonance fluoroscopy reduces the time needed for the intervention. We recommend the coil-marking technique.

Entities:  

Mesh:

Year:  2004        PMID: 15292425     DOI: 10.2106/00004623-200408000-00021

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  2 in total

1.  Numerical simulations of intra-voxel dephasing effects and signal voids in gradient echo MR imaging using different sub-grid sizes.

Authors:  Bernd M Müller-Bierl; Hansjörg Graf; Philippe L Pereira; Fritz Schick
Journal:  MAGMA       Date:  2006-05-09       Impact factor: 2.310

2.  Virtual 3D tumor marking-exact intraoperative coordinate mapping improve post-operative radiotherapy.

Authors:  Harald Essig; Majeed Rana; Andreas Meyer; André M Eckardt; Horst Kokemueller; Constantin von See; Daniel Lindhorst; Frank Tavassol; Martin Ruecker; Nils-Claudius Gellrich
Journal:  Radiat Oncol       Date:  2011-11-16       Impact factor: 3.481

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.